ESD200 Flammable EX LEL VOC Gas Detector

ESD200 Flammable EX LEL VOC Gas Detector

The ESD200 is a high-precision fixed gas detector designed for industrial and commercial environments. It supports detection of flammable gases, toxic gases and VOCs, adopting catalytic combustion, electrochemical and PID detection principles. With stable performance and diverse detection ranges, it meets long-term, continuous gas leakage monitoring needs for multiple scenarios.

Send Inquiry
Product Description

Introduction of ESD200 Flammable EX LEL VOC Gas Detector

The ESD200 is a high-precision fixed gas detector designed for industrial and commercial environments. It supports detection of flammable gases, toxic gases and VOCs, adopting catalytic combustion, electrochemical and PID detection principles. With stable performance and diverse detection ranges, it meets long-term, continuous gas leakage monitoring needs for multiple scenarios.

 

Engineered for harsh working conditions, this detector features full certifications and excellent environmental adaptability. It delivers accurate and repeatable detection data, with fast response speed, effectively eliminating potential safety hazards in gas leakage and ensuring operational safety for factories and laboratories.

 

Feature of ESD200 Flammable EX LEL VOC Gas Detector

1) Multi-gas Compatibility: It detects flammable gases (0-100% LEL), various toxic gases and VOCs, covering 18 common industrial gases to suit diverse monitoring demands.

 

2) Certified Safety Performance: It obtains professional Ex explosion-proof, CPA metering, fire safety and CE certifications, compliant with national and international industry standards for reliable operation.

 

3) High Detection Accuracy: It achieves ±3% LEL/±3%FS accuracy and ≤2% repeatability, with T90 response time within 20s for flammable gases, ensuring real-time and precise monitoring.

 

4) Flexible Communication & Output: Equipped with HART communication and optional 4-20mA signal output, plus 3 groups of alarm/fault relays, it supports seamless connection with industrial control systems.

 

5) Easy Maintenance & Durability: Adopts replaceable sensor design with long service life. IP66 waterproof and dustproof grade works stably at -40℃ to 70℃ for wide environmental adaptability.

 

Detail photos of GTYQ-ESD200 Flammable Gas Detector

ESD200 Flammable EX LEL VOC Gas Detector

ESD200 Flammable EX LEL VOC Gas Detector

 

ESD200 Flammable EX LEL VOC Gas Detector

 

Product parameters of ESD200 Flammable EX LEL VOC Gas Detector

Performance
Detectable Gas Combustible gas / Toxic gas / VOC / Other gases
Detection Principle Catalytic combustion / Electro‑chemical / PID
Measurement Range 0%~100% LEL (combustible gas); see the table below for other gases
Accuracy ±3% LEL (combustible gas) / ±3%FS (toxic gas)
Repeatability ≤ 2 %
Response Time T90 < 20 s (catalytic combustion); see the table below for other principles
Electrical Characteristics
Power Consumption < 2.5 W (combustible gas, without sound‑light alarm); < 1.5 W (toxic gas, without sound‑light alarm)
Power Supply 24 VDC (operating voltage range: 10‑30 VDC)
Output Signal 3‑wire 4‑20 mA / 2‑wire 4‑20 mA (toxic gas); optional HART digital communication; alarm / fault relay: 1A @ 24 VDC (3 groups)
Mechanical & Structural Characteristics
Housing Material ADC12 aluminum alloy / 316 stainless steel
Process Thread M20×1.5, 1/2 NPT internal thread; optional: G3/4, G1/2, 3/4 NPT
Weight 1.5 kg (Al‑alloy, with sound‑light alarm) / 1.42 kg (Al‑alloy, without sound‑light alarm)
  3.48 kg (Stainless‑steel, with sound‑light alarm) / 3.4 kg (Stainless‑steel, without sound‑light alarm)
Certifications
Explosion‑proof Certificate

Exd ⅡC T6 Gb / Ex tD A21 IP66 T80 °C (combustible gas detector)

Exd ib ⅡC T6 Gb / Ex tD ibD A21 IP66 T80 °C (toxic gas detector)

Fire‑protection Certificate Fire-product certification
Metrology Certification CPA
CE Certificate CE
Applicable Standards GB15322.1-2019,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010, GB12476.1-2013, GB12476.4-2010,GB12476.5-2013,JJF1368-2012,GB/T 4208-2017
Environmental Operating Conditions
Ingress Protection IP66
Ambient Temperature -40 °C~70 °C (combustible gas); ‑20 °C ~ 50 °C (toxic gas)
Humidity 10‑95%RH (non-condensing)
Ambient Pressure 86‑106 kPa
Alarm Thresholds (Factory Default) Low-level alarm: 25%FS; High-level alarm: 50%FS
Sensor Service Life Catalytic sensor: 5 years (in clean atmosphere)
Electro-chemical sensor: ≥1 year (in clean atmosphere)
PID lamp: ≥5000 hours (in clean atmosphere)

 

ESD200 Detectable Toxic Gases List

No. Gas Name Chemical Formula Measurement Range (ppm) Response Time (s) Recovery Time (s) 
T50 T90 T10
1 Oxygen O2 0-25%VOL <10 <25 <20
2 Carbon monoxide CO 0-100/200/500/1000 <15 <25 <45
3 Hydrogen sulfide H2S 0-20/50/100 <10 <30 <40
4 Hydrogen H2 1000 <20 <50 <60
5 Ammonia NH3 0-100/500/1000 <40 <90 <120
6 Chlorine CL2 0-10/20 <30 <50 <60
7 Nitric oxide NO 0-100/500 <10 <30 <90
8 Nitrogen dioxide NO2 0-20/50 <40 <90 <90
9 Sulfur dioxide SO2 0-20/100 <15 <40 <90
10 Vinyl chloride C2H3CL 0-20/100 <35 <90 <180
11 Acrylonitrile C3H3N 0-100/200 <80 <160 <180
12 Methanol CH3OH 0-100/200/500 <20 <80 <150
13 Formaldehyde CH2O 0-50/100/200/500 <25 <70 <150
14 Ethylene oxide C2H4O 0-20/100/200 <50 <120 <180
15 Hydrogen chloride HCL 0-30/50 <50 <80 <120
16 Hydrogen fluoride HF 0-10 <30 <90 <120
17 Hydrogen cyanide HCN 0-30 <40 <90 <120
18 Tetrahydrothiophene C4H8S 0-30 <20 <60 <120

 

FAQ about ESD200 Flammable EX LEL VOC Gas Detector

Q1: What gases can the ESD200 detect? 

A1: It covers flammable gases, VOCs and 18 types of toxic gases including CO, H2S, O2, NH3 and formaldehyde.

 

Q2: Is it suitable for hazardous explosive areas? 

A2: Yes. It holds complete Ex explosion-proof certifications, specially designed for flammable and explosive industrial sites.

 

Q3: What is the working temperature range? 

A3: It works from -40℃ to 70℃ for flammable gases and -20℃ to 50℃ for toxic gases, adapting to most industrial environments.

 

Q4: How about the sensor service life? 

A4: Catalytic sensors last 5 years, electrochemical sensors over 1 year, and PID bulbs over 5000 hours in clean environments.

 

Q5: Does it support real-time on-site viewing? 

A5: Yes. Built-in LCD screen displays real-time gas data on-site for intuitive and convenient on-site checking.