Product Description
Introduction of Fixed Flammable Gas Detector ATEX
The CGT-CO2000 fixed gas detector is an ATEX and IECEx certified explosion-proof monitoring device engineered for industrial hazardous environments. Designed and manufactured by Sichuan Xuxin Technology, this robust detector is specially optimized for energy storage scenarios including energy storage power stations, containers and cabinets, delivering real-time continuous monitoring of carbon monoxide (CO) concentration in battery compartments.
Featuring a flameproof Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db explosion-proof grade, the device is applicable to Zone 1/2 hazardous areas and adapts to IIA, IIB, IIC gas and dust environments with a wide working temperature range of -40℃ to +70℃. Equipped with a high-precision electrochemical sensor and natural diffusion sampling mode, it provides stable CO detection within the range of 0 to 2000×10⁻⁶ volume fraction. With IP66 full waterproof and dustproof protection, it operates reliably in high humidity (5%-95%RH) and variable atmospheric pressure (86-106kPa) conditions, ensuring long-term stable operation in harsh industrial scenarios.
Feature of Fixed Flammable Gas Detector ATEX
This ATEX-certified gas detector stands out in industrial safety monitoring with multiple industry-leading advantages, balancing high precision, low maintenance and strong compatibility.
First, it boasts ultra-long service life and maintenance-free performance. The original electrochemical sensor supports a 10-year service life under normal monitoring conditions, with factory pre-calibration enabling plug-and-play use. It requires no regular calibration or daily maintenance, greatly reducing later operation and maintenance costs and downtime risks.
Second, it delivers reliable and accurate detection performance. The detector features a 1×10⁻⁶ high resolution and controllable zero drift (≤50×10⁻⁶), with a detection error within ±10% of the measured value or ±100×10⁻⁶ (maximum value). It supports two-stage alarm logic: default low alarm at 200×10⁻⁶ and high alarm at 500×10⁻⁶, with clear LED visual alerts visible beyond 5 meters in darkness for timely risk warning.
Third, it has excellent industrial compatibility and expandability. Supporting 18-32VDC wide voltage power supply (rated 24VDC) and low power consumption (≤1W), it adapts to various industrial power supply systems. It integrates RS485 (9600bps) communication and dual dry contact relays, allowing up to 32 detectors to be connected in a single bus network via hand-in-hand wiring for unified system monitoring. The built-in 120Ω matching resistor is optional via jumper cap to adapt to different on-site wiring conditions.
Fourth, it adopts rugged industrial-grade design. The die-cast aluminum alloy shell provides strong anti-corrosion and anti-collision capability. Strict certifications including ATEX, IECEx, CE and RoHS ensure full compliance with EU industrial safety standards. Professional grounding and anti-static design, together with standardized explosion-proof structure, completely meet hazardous area operation specifications.
Detail photos of Fixed Flammable Gas Detector ATEX



Product parameters of Fixed Flammable Gas Detector ATEX
| Type | Specific parameters |
| Appearance parameter | |
| Pigment | dark grey |
| Shell material | die-casting aluminium |
| Outline dimension | approximately 100 mm × 78 mm × 53 mm |
| Product weight | approximately 415 g |
| Function parameter | |
| Test gas | CO(carbon monoxide) |
| Sensor type | electrochemical sensor |
| Sample mode | natural diffusion |
| Detection range | (0~2000)×10-6 (volume fraction) |
| Operate mode | continuous monitoring |
| Alarm value setting range (Two-level alarm) |
The minimum alarm threshold for production output is set at 200×10-6 (volume fraction). The maximum alarm threshold for the outlet concentration is set at 500×10-6 (volume fraction). |
| Alarm error | ±50×10-6 (volume fraction) |
| Range indication deviation | allowable error: ±80×10-6 (volume fraction) |
| Alarming light visibility | > 5 m (in darkness) |
| Response time | ≤ 30s |
| Call time | ≤ 15s |
| Resolution ratio | 1×10-6 (volume fraction) |
| Zero drift range | ≤50×10-6 (volume fraction) |
| Sensor service life | normal monitoring environment for 15 years |
| Electrical parameters | |
| Working voltage | 18VDC-32VDC |
| Rated voltage | 24VDC |
| Power dissipation | ≤ 1W |
| Working current | ≤ 5 mA |
| Alarm current | ≤ 25mA |
| Maximum current | ≤ 25mA |
| Output signal | RS485 (optional) [The communication address defaults to 1 at factory; a built-in 120Ω matching resistor is not connected by default and can be enabled using a jumper cap] |
| Baud rate | 9600 bps |
| Dry contact 1 – Low alarm relay | Group 1: Contact capacity (resistance load): 1A @30VDC; 300 mA @ 125VAC. Factory default: Open during normal operation, close during alarms, open during power loss. |
| Dry contact 2 – High alarm relay | Group 1: Contact capacity (resistance load): 1A @30VDC; 300 mA @ 125VAC. Factory default: Open during normal operation, close during alarms, open during power loss. |
| Indicate way | |
| Pilot lamp | 3 LED status lights |
| State indication | 1. During normal operation: The green indicator light remains illuminated continuously |
| 2. In case of a malfunction: The yellow indicator light remains constantly illuminated. | |
| 3. Alarm indication: When the lower limit is exceeded, a red light flashes; when the upper limit is exceeded, the red light remains on continuously. | |
| 4. During the upgrade process: Red, yellow, and green lights will flash alternately. | |
| Upgrade and configuration parameters | Can be connected to a computer via the RS485 bus (optional) |
| Certification and protection level | |
| Attestation | ROHS, CE ,ATEx, IECEx |
| Protect grade | IP66 |
| Explosion-proof mark |
II2 G Ex db IIC T6 Gb II2 D Ex tb IIIC T80°C Db |
FAQ about Fixed Flammable Gas Detector ATEX
Q1: What scenarios is this ATEX gas detector suitable for?
It is mainly designed for CO concentration monitoring in energy storage systems such as battery compartments, energy storage containers and energy storage cabinets. It also applies to Zone 1/2 explosive gas and dust environments, covering all industrial scenarios requiring flammable and toxic gas safety monitoring.
Q2: Does the device require regular calibration and maintenance?
No daily calibration or maintenance is needed. The detector is fully calibrated before factory delivery. After reaching the design service life, users only need to conduct annual standard gas testing. It can continue operating if detection error meets the standard requirements.
Q3: What are the alarm status indications?
It adopts three-color LED status prompts: green light steady on for normal operation, yellow light steady on for device fault, red light flashing for low-concentration alarm and red light steady on for high-concentration alarm. The three lights flash simultaneously during program upgrade for clear status identification.
Q4: What are the key installation and safety precautions?
Installation and commissioning must be completed by professional technicians with power off operation. The shell grounding terminal must be reliably grounded (ground resistance <4Ω). It is forbidden to open the shell with power on, block the air inlet, or expose the device to high-concentration CO, silicone substances and corrosive gases to avoid permanent sensor damage.
Q5: What is the maximum networking capacity?
A single RS485 bus can connect up to 32 detectors in hand-in-hand mode. Only one detector in the whole network needs to enable the 120Ω terminal resistor to ensure stable communication.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese