Product Description
Introduction of Gas Detection for Battery Rooms
The CGT-H2100 hydrogen gas detector is a professional, explosion-proof monitoring device specially designed for battery room and energy storage system scenarios. It focuses on real-time hydrogen concentration monitoring in battery cabins, energy storage containers and cabinet environments to eliminate safety hazards caused by battery thermal runaway and hydrogen accumulation. Adopting advanced thermal conduction sensing technology and natural diffusion sampling mode, the device supports continuous 24-hour gas detection with a measuring range of 0–100% LEL and a high resolution of 0.1% LEL, ensuring precise and stable monitoring data.
Certified with CE, ROHS, ATEx and IECEx, the detector features a robust explosion-proof design with the marks II 2 G Ex db IIC T6 Gb and II 2 D Ex tb IIIC T80℃ Db, suitable for Zone 1/2 hazardous gas and dust environments. It operates stably in extreme conditions with temperatures from -40℃ to +70℃ and 5%–95% RH humidity, fully adapting to the complex and variable operating environments of energy storage stations. Equipped with dual-level alarm functions, it sets 10% LEL low alarm and 25% LEL high alarm by default, and feeds back alarm signals through indicator lights and dry contacts to trigger timely emergency responses.
Feature of Gas Detection for Battery Rooms
1) Ultra-long Service Life and Maintenance-free Design
Featuring a 15-year sensor service life in conventional monitoring environments, the device supports factory calibration-free and daily maintenance-free operation, greatly reducing post-operation maintenance costs and manual investment. After reaching the conventional service cycle, it can continue to be used if it meets the accuracy standards through annual standard gas testing, realizing ultra-long cycle reuse.
2) High Precision and Strong Environmental Adaptability
With a detection error of ±5% LEL and zero drift ≤3% LEL, the device ensures accurate and reliable monitoring data. The IP66 high-protection enclosure made of die-cast aluminum alloy effectively resists dust, water splash and environmental corrosion. It supports stable operation under 86–106 kPa atmospheric pressure, adapting to various outdoor and indoor energy storage scenarios.
3) Flexible Wiring and Stable Networking
It adopts 18–32 VDC wide voltage power supply (24 VDC rated) with low power consumption (≤1 W), supporting long-term energy-saving operation. Equipped with standard RS485 communication (9600 bps baud rate) and dual dry contact alarm outputs, it realizes two-way data interaction and alarm signal upload with the host system. A single RS485 bus can connect up to 32 detectors in a hand-in-hand networking mode, with selectable 120Ω terminal resistance to adapt to different on-site wiring conditions.
4) Intuitive Status Indication and Safe Operation
Three LED indicator lights clearly display device status: green light for normal operation, yellow light for fault alert, and red light for hydrogen concentration alarm (flashing for low alarm, steady on for high alarm). The whole device supports remote parameter configuration and address editing via infrared remote control, with simple operation and no need for frequent disassembly. Strict explosion-proof and anti-static design, as well as standardized grounding specifications, ensure zero safety risks during on-site installation and operation.
Detail photos of Gas Detection for Battery Rooms



Product parameters of Gas Detection for Battery Rooms
| Type | Specific parameters |
| Appearance parameter | |
| Pigment | dark grey |
| Shell material | die-casting aluminium |
| Outline dimension | approximately 100 mm × 78 mm × 53 mm |
| Product weight | approximately 420 g |
| Function parameter | |
| Test gas | H₂ (hydrogen gas) |
| Sensor type | conduction of heat |
| Sample mode | natural diffusion |
| Detection range | (0~ 100)% LEL |
| Operate mode | continuous monitoring |
| Alarm value setting range (Two-level alarm) |
The minimum factory alarm threshold is set at 10% LEL. The maximum alarm threshold for factory output is set at 25% LEL. |
| Alarm error | ±3%LEL |
| Range indication deviation | allowable error: ± 5% LEL |
| Alarming light visibility | > 5 m (in darkness) |
| Response time | ≤ 15s |
| Call time | ≤ 15s |
| Resolution ratio | 0. 1%LEL |
| Zero drift range | ≤ 3%LEL |
| Sensor service life | normal monitoring environment for 15 years |
| Electrical parameters | |
| Working voltage | 18VDC-32VDC |
| Rated voltage | 24VDC |
| Power dissipation | ≤ 1W |
| Working current | ≤ 15 mA |
| Alarm current | ≤ 35mA |
| Maximum current | ≤ 35mA |
| Output signal | RS485 (optional) [The communication address defaults to 1 at factory; a built-in 120Ω matching resistor is not connected by default and can be enabled using a jumper cap] |
| Baud rate | 9600 b ps |
| Dry contact 1 – Low alarm relay |
Group 1: Contact capacity (resistance load): 1A @30VDC; 300 mA @ 125VAC. Factory default: Open during normal operation, close during alarms, open during power loss. |
| Dry contact 2 – High alarm relay | Group 1: Contact capacity (resistance load): 1A @30VDC; 300 mA @ 125VAC. Factory default: Open during normal operation, close during alarms, open during power loss. |
| Indicate way | |
| Pilot lamp | 3 LED status lights |
| State indication | 1. During normal operation: The green indicator light remains illuminated continuously |
| 2. In case of a malfunction: The yellow indicator light remains constantly illuminated. | |
| 3. Alarm indication: When the lower limit is exceeded, a red light flashes; when the upper limit is exceeded, the red light remains on continuously. | |
| 4. During the upgrade process: Red, yellow, and green lights will flash alternately. | |
| Upgrade and configuration parameters | Can be connected to a computer via the RS485 bus (optional) |
| Certification and protection level | |
| Attestation | ROHS, CE ,ATEx, IECEx |
| Protect grade | IP66 |
| Explosion-proof mark |
II2 G Ex db IIC T6 Gb II2 D Ex tb IIIC T80°C Db |
FAQ about Gas Detection for Battery Rooms
Q1: Does the detector require regular calibration and daily maintenance?
A1: No. The CGT-H2100 detector is factory-calibrated and supports long-term calibration-free and maintenance-free operation. Users only need to regularly clean the air inlet to avoid dust blockage. After 15 years of conventional use, annual accuracy testing is recommended, and the device can continue to be used if it meets the error standards.
Q2: What scenarios is this hydrogen detector suitable for?
A2: It is specially developed for energy storage scenarios, widely applicable to battery rooms, energy storage containers, energy storage cabinets and other battery energy storage systems. It adapts to Zone 1/2, IIA/IIB/IIC gas and dust hazardous environments, covering all conventional commercial and industrial energy storage station application scenarios.
Q3: What should be noted during installation and wiring?
A3:Installation and wiring must be completed by professional technicians under power-off status with anti-static measures. The shell must be reliably grounded (grounding resistance <4Ω), and RS485 shielded twisted pair is required for signal wiring. Only one detector in the entire bus network needs to access the 120Ω terminal resistance to ensure stable communication.
Q4: What factors will affect the detection accuracy?
A4: Sudden changes in background gas thermal conductivity, liquid condensation impact, long-term exposure to helium gas or alkaline corrosive gas, and blocked air inlet will cause data deviation. Avoiding the above situations can maintain long-term detection accuracy and sensor stability.
Q5: How to deal with common device faults?
A5: If the power indicator is off, check the power supply voltage and wiring integrity; if the fault light is on, inspect the power stability or replace the device; if communication fails, troubleshoot open/ reversed communication wiring and duplicate device addresses. Most on-site faults can be quickly eliminated through simple line inspection.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese