Product Description
Introduction of Industrial Hydrogen Gas Detector
Southeast Asia’s industrial sectors, including petrochemical, manufacturing and energy processing, face persistent safety risks from flammable gas leaks. High temperature, high humidity and complex factory environments further challenge gas detection stability and accuracy, while strict regional safety regulations require continuous, reliable gas monitoring for factory zones 1 and 2.
The GTYQ-X01 Industrial Point-type Combustible Gas Detector is a professional fixed detection solution tailored for harsh industrial scenarios. It adopts a split structure with a main body and pluggable sensor module, supporting 24/7 continuous monitoring of hydrogen, methane, propane and other flammable gases. Equipped with a real-time display screen and infrared remote control function, it enables on-site gas concentration viewing, zero adjustment, calibration and parameter setting without equipment disassembly. Certified with Ex db IIC T6 Gb explosion-proof grade, it fully complies with safety standards for IIA, IIB, IIC gas environments and T1-T6 temperature groups, perfectly adapting to mainstream industrial hazardous scenarios in Southeast Asia.
Feature of Industrial Hydrogen Gas Detector
1) Tropical Extreme Environment Resistance
Adapted to Southeast Asia’s high-temperature, high-humidity and coastal salt fog climate, the detector supports stable operation at -40℃ to +70℃ and 95% non-condensing humidity. Adopting IP66 high protection grade and die-cast aluminum alloy anti-corrosion shell, it effectively resists dust, rain and salt fog erosion, avoiding frequent equipment faults caused by harsh tropical weather and cutting seasonal maintenance costs.
2) High-precision & Reliable Detection
Equipped with mature catalytic combustion sensing technology, it achieves 0.1%LEL high-resolution detection within 3%LEL–100%LEL range. With ultra-low errors (±5%LEL full-scale deviation, ≤±3%LEL alarm error) and ≤30s fast response, it avoids false and missed alarms. The dual-level alarm system (25%LEL low alarm / 50%LEL high alarm) meets hierarchical safety early warning requirements for local industrial sites.
3) Low O&M Cost & Easy Maintenance
Featuring a pluggable sensor module, it supports tool-free quick replacement to shorten maintenance downtime. The sensor enjoys a 3-year long service life, greatly reducing long-term replacement expenses. Standard DC24V power supply and 9600bps RS485 output ensure wide compatibility with most local industrial monitoring systems, realizing seamless docking and lowering equipment upgrade costs.
4) Full Safety Compliance & Simple Operation
With high-level Ex db IIC T6 Gb explosion-proof certification, it complies with safety standards for Zone 1/2 hazardous areas and IIA/IIB/IIC gas environments, meeting mandatory inspection requirements in Malaysia, Indonesia, Thailand and other Southeast Asian countries. Infrared remote control one-key calibration and parameter setting simplifies on-site debugging, improving operational efficiency.
Detail photos of Industrial Hydrogen Gas Detector




Product parameters of Industrial Hydrogen Gas Detector
| Item | Parameter Description |
| Product Name | GTYQ-X01 Industrial and Commercial Point-type Combustible Gas Detector |
| Explosion-proof Type | Flameproof |
| Explosion-proof Mark | Ex db IIC T6 Gb |
| Test Gas | Combustible gas (Methane, Hydrogen, Propane) |
| Sensor Type | Catalytic Combustion Type |
| Sampling Method | Natural Diffusion |
| Detection Range | 3%LEL ~ 100%LEL |
| Resolution | 0.1%LEL |
| Operating Voltage | DC24V (±15%) |
| Operating Mode | Continuous Detection |
| Range Indication Deviation | Allowable Error: ±5%LEL |
| Alarm Value Setting Range | (Two-stage Alarm) Factory default low alarm set value: 25%LEL; Factory default high alarm set value: 50%LEL |
| Alarm Error | ≤±3%LEL |
| Alarm Light Visibility | More than 5 meters (in dark environment) |
| Response Time | ≤30s |
| Sensor Service Life | ≤3 years under normal monitoring environment |
| Housing Material | Die-cast Aluminum Alloy |
| Overall Dimension | Approx. 136.8mm×112.5mm×73mm |
| Product Weight | Approx. 612g |
| Output Signal | RS485 |
| Baud Rate | 9600 bps |
| Temperature Range | -40℃ ~ +70℃ |
| Relative Humidity | ≤95% (Non-condensing) |
| Atmospheric Pressure | 86 kPa ~ 106kPa |
| Ingress Protection | Rating IP66 |
| Application | Site Suitable for Zone 1 and Zone 2, IIA, IIB and IIC class gas environments |
FAQ about Industrial Hydrogen Gas Detector
Q1: Can it work stably in Southeast Asia’s high humidity and coastal salt fog environments?
A1: Yes. With IP66 protection grade and corrosion-resistant die-cast aluminum shell, it adapts to 95% non-condensing high humidity and coastal salt fog environments. It maintains stable detection performance in long-term high-temperature and humid tropical conditions, effectively reducing weather-induced equipment failures.
Q2: Is the device suitable for hydrogen gas monitoring in industrial hazardous zones?
A2: Absolutely. It supports accurate detection of hydrogen and other mainstream flammable gases, with Ex db IIC T6 Gb explosion-proof grade applicable to Zone 1/2 hazardous areas and IIC high-risk gas environments, fully meeting hydrogen industry safety monitoring requirements.
Q3: Is daily maintenance complicated for factory staff?
A3: Very simple. The pluggable sensor module enables tool-free quick replacement. Infrared remote control realizes on-site zero adjustment, calibration and parameter setting. The 3-year long sensor service life minimizes maintenance frequency, lowering technical and cost thresholds for local factory operation.
Q4: Can it connect with existing factory monitoring systems?
A4: Yes. Standard RS485 signal output with 9600bps fixed baud rate ensures strong compatibility with mainstream industrial control and monitoring systems in Southeast Asia, supporting quick system docking without complex transformation.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese