Product Description
Introduction of LEL Gas Detector Industrial
The GTYQ-X01 industrial and commercial point-type combustible gas detector is a professional safety monitoring device tailored for hazardous gas environments. It consists of a main detector body and a pluggable gas sensor module, supporting continuous, real-time monitoring of flammable gas leaks in ambient air. Equipped with a high-definition display, it intuitively shows real-time gas concentration and equipment operating status, while supporting infrared remote control for zero adjustment, calibration and parameter configuration, enabling convenient non-contact operation.
Certified with Ex db IIC T6 Gb explosion-proof grade, this detector is applicable to Zone 1 and Zone 2 hazardous areas, adapting to IIA, IIB, IIC gas environments and T1-T6 temperature groups. It reliably detects mainstream combustible gases including methane, hydrogen and propane, serving as an essential safety barrier for industrial manufacturing, commercial facilities and other high-risk scenarios.
Feature of LEL Gas Detector Industrial
The GTYQ-X01 detector adopts high-precision catalytic combustion sensors to deliver accurate and stable gas detection. It features a 0.1%LEL high resolution and a full detection range of 3%LEL–100%LEL, with low detection and alarm errors. Equipped with a fast response system within 30 seconds, it can quickly detect flammable gas leaks and issue early warnings to eliminate potential safety risks in time.
Built for harsh industrial scenarios, the detector features a durable die-cast aluminum alloy shell and IP66 high-level protection, offering excellent dustproof, waterproof and anti-corrosion performance. It supports stable operation in extreme environments of -40℃ to +70℃, 86kPa–106kPa air pressure and ≤95% non-condensing humidity. The innovative pluggable sensor module enables tool-free quick replacement, greatly simplifying daily maintenance and lowering long-term operation costs.
It supports practical two-stage audible and visual alarm, with factory default low alarm at 25%LEL and high alarm at 50%LEL. The alarm light is visible beyond 5 meters in dark conditions, ensuring prominent warning effects. Powered by DC24V(±15%) voltage and equipped with standard 9600bps RS485 signal output, the device achieves 24-hour continuous monitoring and seamless connection with industrial monitoring systems for stable and efficient data transmission.
Boasting a 3-year long sensor service life, the detector is cost-effective for long-term use. Its compact and lightweight structure enables flexible and convenient installation, adapting to diverse complex industrial and commercial installation environments.
Detail photos of LEL Gas Detector Industrial




Product parameters of LEL Gas Detector Industrial
| Item | Parameter Description |
| Product Name | GTYQ-X01 Industrial and Commercial Point-type Combustible Gas Detector |
| Explosion-proof Type | Flameproof |
| Explosion-proof Mark | Ex db IIC T6 Gb |
| Test Gas | Combustible gas (Methane, Hydrogen, Propane) |
| Sensor Type | Catalytic Combustion Type |
| Sampling Method | Natural Diffusion |
| Detection Range | 3%LEL ~ 100%LEL |
| Resolution | 0.1%LEL |
| Operating Voltage | DC24V (±15%) |
| Operating Mode | Continuous Detection |
| Range Indication Deviation | Allowable Error: ±5%LEL |
| Alarm Value Setting Range | (Two-stage Alarm) Factory default low alarm set value: 25%LEL; Factory default high alarm set value: 50%LEL |
| Alarm Error | ≤±3%LEL |
| Alarm Light Visibility | More than 5 meters (in dark environment) |
| Response Time | ≤30s |
| Sensor Service Life | ≤3 years under normal monitoring environment |
| Housing Material | Die-cast Aluminum Alloy |
| Overall Dimension | Approx. 136.8mm×112.5mm×73mm |
| Product Weight | Approx. 612g |
| Output Signal | RS485 |
| Baud Rate | 9600 bps |
| Temperature Range | -40℃ ~ +70℃ |
| Relative Humidity | ≤95% (Non-condensing) |
| Atmospheric Pressure | 86 kPa ~ 106kPa |
| Ingress Protection | Rating IP66 |
| Application | Site Suitable for Zone 1 and Zone 2, IIA, IIB and IIC class gas environments |
FAQ about LEL Gas Detector Industrial
Q1: What gases can this detector monitor?
A1: It is professionally calibrated for mainstream combustible gases, including methane, hydrogen and propane, covering most common flammable gas leakage scenarios in industrial and commercial fields.
Q2: Is the detector suitable for harsh outdoor and industrial environments?
A2: Yes. With IP66 dustproof and waterproof grade, robust aluminum alloy shell and wide temperature & humidity adaptability, it can work stably in extreme and harsh industrial environments, fully meeting Zone 1/2 hazardous area application standards.
Q3: How to maintain and calibrate the device?
A3: The detector supports infrared remote control for non-contact zero adjustment, calibration and parameter setting, no need for on-site disassembly. The pluggable sensor module allows quick replacement, greatly simplifying daily maintenance work.
Q4: What is the alarm mechanism of the detector?
A4: It adopts a two-stage alarm design. When gas concentration reaches 25%LEL (low limit) and 50%LEL (high limit), it will trigger a distinct audible and visual alarm with visible light distance over 5 meters, providing timely safety warnings for staff.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese