Product Description
Introduction of Point Type Combustible Gas Detector
The GM-X01 Point Type Combustible Gas Detector is a professional fixed gas monitoring device tailored for industrial and commercial scenarios, perfectly adapting to the harsh operating environments and safety compliance requirements of Southeast Asian factories, chemical plants, processing workshops and commercial facilities. Designed with a split structure of a main body and a pluggable gas sensor module, this detector delivers continuous, real-time monitoring of carbon monoxide (CO) leakage in the ambient air, with on-screen display of real-time gas concentration and equipment operating status.
Engineered for hazardous explosive environments, the detector features an Ex db IIC T6 Gb explosion-proof rating, covering Zone 1 and Zone 2 hazardous areas and compatible with IIA, IIB, IIC gas groups and T1-T6 temperature groups. It adopts a natural diffusion sampling method and a high-precision electrochemical sensor, with a detection range of 0~1000×10⁻⁶ volume fraction, fully meeting the daily gas safety monitoring standards of industrial and commercial sites in Southeast Asia. Supporting infrared remote control for zero adjustment, calibration and parameter setting, it simplifies on-site debugging operations while ensuring stable and long-term continuous detection with a DC24V (±15%) working voltage and low power consumption design.
Feature of Point Type Combustible Gas Detector
1) Excellent Environmental Adaptability for Tropical Climate
Most Southeast Asian regions feature year-round high temperature, high humidity and coastal humid air, which easily causes drift, failure or short service life of ordinary gas detectors. The GM-X01 is professionally optimized for tropical harsh environments, supporting stable operation at -10℃ to +55℃ and relative humidity up to 95% (non-condensing). Its IP66 high protection grade and die-cast aluminum alloy shell effectively resist dust, water splash and humid corrosion, avoiding frequent equipment failures and calibration drift caused by humid weather, greatly reducing field maintenance frequency in high-humidity scenarios.
2) Full Explosion-Proof Compliance & Wide Application Coverage
Southeast Asian industrial safety regulations impose strict requirements on hazardous area equipment certification. With authoritative Ex db IIC T6 Gb explosion-proof certification, the detector is applicable to Zone 1 and Zone 2 explosive hazardous areas, covering all conventional flammable gas environment types in local chemical, manufacturing, storage and processing industries. It fully complies with regional industrial safety standards, helping enterprises pass safety inspections smoothly and eliminate hidden safety hazards in hazardous working areas.
3) High Detection Accuracy & Reliable Alarm Performance
Equipped with a high-stability electrochemical sensor, the device ensures precise CO gas monitoring with a detection error within ±80×10⁻⁶ and alarm error controlled within ±50×10⁻⁶. It supports two-stage alarm settings, with factory default low alarm at 200×10⁻⁶ and high alarm at 500×10⁻⁶, matching mainstream industrial safety threshold standards. The response time is ≤30s, enabling rapid capture of gas leakage. The alarm light provides visibility over 5 meters in dark environments, ensuring timely alarm reminders even in dim workshop and storage spaces to avoid safety accidents caused by delayed leakage detection.
4) Low Operation & Maintenance Cost, High Cost-Effectiveness
A major pain point for Southeast Asian small and medium-sized industrial enterprises is the high long-term maintenance cost of gas detection equipment. The GM-X01 adopts a pluggable sensor module design, enabling quick replacement and calibration without professional complex operations, saving labor and time costs for on-site maintenance. The sensor service life reaches up to 3 years under normal monitoring conditions, far reducing the frequency of sensor replacement. With ultra-low power consumption (maximum working current 10mA) and stable RS485 9600bps signal output, it supports long-term uninterrupted operation and seamless connection with industrial monitoring systems, avoiding extra equipment upgrade and integration costs.
5) Simple Operation & Stable System Performance
The detector supports infrared remote control one-key zero adjustment, calibration and parameter setting, eliminating the need for professional debugging tools and lowering the technical threshold for on-site operation. It adopts continuous working mode with stable and reliable operation, no frequent false alarms or missed alarms, avoiding production shutdown losses caused by misjudgment of gas concentration. The compact and lightweight design (136.8mm×112.5mm×73mm, 616g) facilitates flexible installation in various narrow and complex industrial layouts.
Detail photos of Point Type Combustible Gas Detector



Product parameters of Point Type Combustible Gas Detector
| Parameter Name | Technical Specification |
| Product Name | GM-X01 Industrial and Commercial Point-Type Combustible Gas Detector |
| Explosion-proof Type | Flameproof |
| Explosion-proof Mark | Ex db IIC T6 Gb |
| Test Gas | CO (Carbon Monoxide) |
| Sensor Type | Electrochemical Sensor |
| Sampling Method | Natural Diffusion |
| Detection Range | 0~1000×10-6 (Volume Fraction) |
| Operating Voltage | DC24V(±15%) |
| Operating Mode | Continuous Detection |
| Range Indication Deviation | Allowable Error: ±80×10-6 (Volume Fraction) |
| Alarm Value Setting Range (Two-stage Alarm) | Factory default low-level alarm setting value: 200×10-6 (volume fraction); Factory default high-level alarm setting value: 500×10-6 (volume fraction). |
| Alarm Error | ≤±50×10-6 (Volume Fraction) |
| Alarm Light Visibility | > 5m (In Darkness) |
| Response Time | ≤30s |
| Sensor Service Life | ≤3 years under normal monitoring environment |
| Housing Material | Die-cast Aluminum Alloy |
| Overall Dimension | Approx. 136.8mm×112.5mm×73mm |
| Product Weight | Approx. 616g |
| Maximum Operating Current | 10mA |
| Output Signal | RS485 |
| Baud Rate | 9600 bps |
| Temperature Range | -10℃~+55℃ |
| Relative Humidity | ≤95% (Non-condensing) |
| Atmospheric Pressure | 86 kPa~106kPa |
| Ingress Protection Rating | IP66 |
| Application Site | Suitable for Zone 1 and Zone 2, IIA, IIB and IIC gas environments |
FAQ about Point Type Combustible Gas Detector
Q1: Is the detector suitable for high temperature and high humidity working environments in Southeast Asia?
A1: Yes. The GM-X01 is specially optimized for tropical harsh climates. It works stably at -10℃ to +55℃ and 95% non-condensing humidity. The IP66 protection grade and anti-corrosion aluminum alloy shell effectively resist humid, dusty and coastal corrosive environments, solving the common problem of short service life and performance drift of ordinary detectors in Southeast Asian high-humidity scenarios.
Q2: Can it meet local industrial explosion-proof and safety compliance requirements?
A2: Absolutely. It holds Ex db IIC T6 Gb full explosion-proof certification, applicable to Zone 1/2 hazardous areas and all IIA/IIB/IIC flammable gas environments. It fully conforms to mainstream industrial safety inspection standards in Southeast Asia, helping local enterprises complete safety compliance verification efficiently.
Q3: How to reduce daily maintenance costs for long-term use?
A3: The pluggable sensor module supports quick disassembly, replacement and calibration, reducing professional maintenance labor costs. The 3-year long sensor service life lowers replacement frequency, and ultra-low power consumption cuts daily operating energy costs. Simple remote debugging also avoids expensive on-site technical service fees.
Q4: Is the equipment compatible with local industrial monitoring systems?
A4: Yes. It adopts standard RS485 signal output with 9600bps baud rate, which is highly compatible with most conventional industrial control and monitoring systems in Southeast Asia, realizing stable data transmission and centralized monitoring without additional conversion equipment.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese