Compact Handheld Combustible Gas Detector

Compact Handheld Combustible Gas Detector

This compact handheld combustible gas detector is a portable, high-precision monitoring device designed for hazardous explosive gas environments. It reliably detects combustible gas (EX), oxygen, carbon monoxide and hydrogen sulfide, supporting continuous real-time monitoring in petrochemical, fire rescue, shipping and steel industries. With Ex d ia IIC T4 Gb explosion-proof certification, it adapts to 0/1/2 zone explosive environments, delivering stable safety detection for industrial operation sites.

Send Inquiry
Product Description

Introduction of Compact Handheld Combustible Gas Detector

This compact handheld combustible gas detector is a portable, high-precision monitoring device designed for hazardous explosive gas environments. It reliably detects combustible gas (EX), oxygen, carbon monoxide and hydrogen sulfide, supporting continuous real-time monitoring in petrochemical, fire rescue, shipping and steel industries. With Ex d ia IIC T4 Gb explosion-proof certification, it adapts to 0/1/2 zone explosive environments, delivering stable safety detection for industrial operation sites.

 

Built with premium sensors and intelligent micro-control systems, the device converts gas concentration signals into accurate digital readings displayed on the screen. It operates stably in harsh conditions of -20℃ to 40℃ and ≤98% humidity, with IP68 waterproof and dustproof grade. Weighing only 248g with an ergonomic compact body, it enables long-time handheld carrying and on-site operation without burden.

 

Equipped with comprehensive safety alarm mechanisms, the detector integrates sound, light and vibration triple alarms to promptly warn of gas concentration abnormalities. It also supports fall detection, linkage alarm and manual emergency alarm, realizing multi-dimensional safety protection for operators. With 100,000 data storage capacity and adjustable sampling intervals, it meets daily monitoring and data recording demands.

 

Feature of Compact Handheld Combustible Gas Detector

1) High Precision & Fast Response: Adopts professional dedicated sensors with long service life (over 2 years for most sensors). It delivers accurate detection with low error and fast T90 response, quickly capturing gas concentration changes to avoid safety risks.

 

2) Multi-Functional Safety Protection: Features dual-level adjustable alarm thresholds, fall reminder and 100m wireless linkage alarm. The one-key calibration and calibration reminder functions ensure long-term detection accuracy and standardized use.

 

3) Durable & Harsh-Resistant: Boasts IP68 high protection grade and strict explosion-proof design. It resists vibration, dust and water, adapting to complex and harsh industrial field environments for stable long-term operation.

 

4) User-Friendly & Long Endurance: Supports 15+ hours of continuous working time. It has adjustable screen-off time, password protection and batch charging cascade functions, with simple operation, convenient data export and low daily maintenance cost.

 

Detail photos of Compact Handheld Combustible Gas Detector

Portable Gas Detector with Data Logging

Portable Gas Detector with Data Logging

Portable Gas Detector with Data Logging

 

Product parameters of Compact Handheld Combustible Gas Detector

Item Parameters
Detectable Gas Type Combustible Gas (EX) Oxygen (O₂) Carbon Monoxide (CO) Hydrogen Sulfide (H₂S)
Detection Range EX: (0~100)%LEL O₂: (0.0~30.0)%VOL CO: (0~2000)×10⁻⁶ H₂S: (0~500)×10⁻⁶
Resolution EX: 1%LEL O₂: 0.1%VOL CO: 1PPM H₂S: 1PPM
Basic Error

EX: 0~100%: ±5%FS

O₂: 0.0~5.0%: ±0.5%O₂; 5.0~30.0%: ±3%FS

CO: (0~20)×10⁻⁶: ±2×10⁻⁶;(>20~100)×10⁻⁶: ±4×10⁻⁶;(>100~500)×10⁻⁶: ±5% of true value;(>500~1000)×10⁻⁶: ±6% of true value;(>1000~2000)×10⁻⁶: ±10% of true value

H₂S: (0~49)×10⁻⁶: ±3×10⁻⁶;(50~500)×10⁻⁶: ±10% of true value

Sensor Service Life

EX: More than 1 year

O₂: More than 2 years

CO: More than 2 years

H₂S: More than 2 years

Alarm Performance Alarm Performance
Alarm Signal Three-dimensional alarm signals: sound, light and vibration
Alarm Sound Intensity >75dB(A) (1 meter away from the buzzer)
Alarm Light Visibility Visible beyond 20m in dark environment
Alarm Point Setting Range (Two-stage Alarm) EX: Full range adjustable; Factory default primary alarm point: 20%LEL, secondary alarm point: 30%LELO₂: Full range adjustable; Factory default primary alarm point: 18.0%O₂, secondary alarm point: 16.0%O₂CO: Full range adjustable; Factory default primary alarm point: 24×10⁻⁶, secondary alarm point: 48×10⁻⁶H₂S: Full range adjustable; Factory default primary alarm point: 10×10⁻⁶, secondary alarm point: 20×10⁻⁶
Alarm Error EX: ±15%LELO₂: ±0.3%O₂CO: ±1×10⁻⁶H₂S: ±3×10⁻⁶
T90 Response Time (Flow rate: 200mL/min) EX: ≤30sO₂: ≤35sCO: ≤45sH₂S: ≤45s
Basic Functions Basic Functions
Fall Alarm When the gas concentration is within the standard range, the instrument can detect the fall of the wearer and display the fall mark;When the gas exceeds the limit, the instrument can detect the wearer's fall and display the fall mark. With the linked alarm function enabled, the fall alarm information will be automatically sent to instruments within 100 meters (visible distance).
Linked Alarm When the linked alarm function is enabled, linkage alarm can be realized within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmission power: ≤20dBm.
Emergency Alarm Long press the emergency alarm button to trigger the manual alarm interface and actively send alarm information to surrounding instruments.
Calibration Reminder When enabled, the instrument will trigger a calibration overdue reminder alarm during startup if the calibration expiration date is reached.
Temperature and Humidity Detection The instrument display interface shows real-time ambient temperature and humidity.
Password Setting 4-digit numeric password available for menu access and shutdown permission; factory default: disabled.
Factory Reset Clear stored data and custom settings to restore factory default configuration.
Screen Off Time Adjustable: 0 (always on) or 1~20 minutes standby screen off time.
Data Storage Automatically collect and store detection data, with a maximum storage capacity of 100,000 records.
Storage Interval Setting The time interval for data collection and storage is adjustable.
Time Setting Supports adjustment of year, month, day, hour and minute.
Data Export Alarm data with timestamp can be exported after connecting the instrument to the charging base.
Cascade Charging The charging base supports cascade connection of 20 units, enabling simultaneous charging of 20 devices with a single adapter.
External Sampling Pump (Optional) Compatible with GSP-200 universal gas sampling pump for remote detection in hazardous areas. It features fast detection speed and ensures operator safety. It is applicable to confined space operations and various safety scenarios, widely used in petrochemical, public utilities, fire rescue, shipping, steel and other industries.
Power Supply Power Supply
Continuous Working Time ≥15 hours under normal working conditions*Actual duration depends on operating status, alarm frequency, indicator light activation, calibration overdue warnings and gas over-limit alarms.
Battery Specification Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: 674048-2240mAh; Maximum open-circuit voltage (Uo): 4.2V; Rated operating voltage (Ue): 3.7V. The battery assembly is encapsulated with epoxy resin after being equipped with two-stage series protection circuits, fuses and current-limiting resistors to form an intrinsic safety battery module.
Dimension and Weight Dimension and Weight
Overall Dimension 115.0mm×63.0mm×32.0mm (excluding back clip)
Weight 248g (including back clip)
Protection Grade Protection Grade
Ingress Protection Rating IP68

 

FAQ about Compact Handheld Combustible Gas Detector

Q1: What gases can this detector monitor?

A1: It detects four common industrial gases: combustible gas (0-100%LEL), oxygen (0.0-30.0%VOL), carbon monoxide (0-2000ppm) and hydrogen sulfide (0-500ppm), covering most industrial safety monitoring scenarios.

 

Q2: Where is the detector applicable?

A2: It suits IIC class explosive gas environments, widely used in petrochemicals, fire rescue, shipping, public utilities and steel industries for on-site safety detection.

 

Q3: How to ensure detection accuracy?

A3: It supports one-key zero calibration and standard gas calibration. The built-in calibration reminder avoids overdue use, and users can manually set calibration cycles to guarantee detection precision.

 

Q4: What alarm functions does it have?

A4: It provides triple sound-light-vibration alarms for gas overload, plus manual emergency alarm, personnel fall alarm and wireless linkage alarm, realizing all-round risk warning.

Leave Your Message


Leave a message