Product Description
Introduction of Handheld Combustible Gas Detector
The Eagle-CO handheld gas detector is an intrinsically safe portable monitoring device engineered for harsh industrial and hazardous environments. Complying with GB3836-2010 and global industry standards, it features an Ex ia IIC T4 Ga explosion-proof rating, supporting continuous real-time monitoring of carbon monoxide concentrations within the 0–2000ppm range. Designed for field personnel, tunnel operations and confined space inspections, it delivers stable and accurate gas detection to prevent gas leakage risks.
Built with high-precision electrochemical sensors, this lightweight detector converts gas concentration signals into intuitive digital readings. It triggers triple visual, audible and vibration alarms once gas levels exceed preset thresholds, ensuring timely hazard warnings. Adaptable to diverse working conditions, it operates steadily at -20℃ to 55℃ with 0–98% humidity and 80–116kPa air pressure, suitable for long-term mobile or fixed on-site use.
Feature of Handheld Combustible Gas Detector
1) Reliable Explosion-Proof & Industrial Grade Safety: Certified with full intrinsic safety, it adapts to IIC-class explosive gas environments, eliminating ignition risks in high-risk working scenarios and fully meeting industrial safety specifications.
2) High Precision & Fast Response: Equipped with durable electrochemical sensors, it achieves ±10%FS indication error and ≤45s response time, with alarm accuracy up to ±1ppm, ensuring sensitive and reliable detection results.
3) Triple Alarm & Customizable Thresholds: It supports two-level concentration alarms, STEL and TWA time-weighted alarms with full-range adjustable values. The 90dB loud alarm and 20-meter visible warning light guarantee effective on-site alerts.
4) Ultra-Long Service Life & Low Maintenance: The CO sensor lasts over 2 years, and the device offers more than 2 years of continuous working time. It supports automatic data storage and infrared data export for convenient safety record tracking.
5) Compact & Rugged Portable Design: Weighing only 116g with IP68 dust and water resistance, it resists vibration and impact. It supports password protection and regular calibration reminders for standardized and secure operation.
Detail photos of Handheld Combustible Gas Detector




Product parameters of Portable Combustible Gas Detector
| Test Gas | Carbon Monoxide (CO) |
| Test Range | CO: (0~2000)×10 |
| Indicating Error | CO: ±10%FS |
| Alarm Point Setting Range | High/Ultra-high limit alarm values: Full-range adjustable for CO; factory default primary alarm point: 24×10 CO; factory default secondary alarm point: 48×10 CO.TWA alarm: Full-range adjustable, factory default alarm point: 24PPM.STEL alarm: Full-range adjustable, factory default alarm point: 24PPM. |
| TWA Time Setting | TWA time adjustable from 4 to 16 hours; factory default value: 8 hours |
| Alarm Error | CO: ±1×10 CO |
| Alarm Sound Intensity | >90dB(A) (measured 1 meter away from the buzzer) |
| Alarm Visibility Distance | >20m in dark environments |
| Response Time (at flow rate of 200mL/min) | CO: ≤45s |
| Ingress Protection Rating | IP68 |
| Sensor Service Life | CO: More than 2 years |
| Continuous Working Time of Instrument | ≥2 years |
| Overall Dimension (excluding back clip) | (excluding back clip) 95.0mm (L) × 53.0mm (W) × 30.0mm (H) |
| Weight | 116g (including back clip) |
| Battery Specification | Intrinsic safety power supply for the instrument: 1 lithium-thionyl chloride battery, Model ER14335-1.65Ah; Rated operating voltage Ue: 3.6V; Maximum open-circuit voltage Uo: 3.7V; Maximum output current Io: 0.51A. |
| Calibration Reminder | When enabled, the instrument will trigger an overdue calibration reminder alarm upon startup if the calibration period expires. |
| Password Setting | 4-digit numeric password available for menu access and shutdown protection; disabled by default |
| Data Storage | Automatic collection data storage |
| Time Setting | Support year, month, day, hour and minute setting |
| Data Export | Infrared export, supporting export of alarm data with specific date and time stamps |
FAQ about Handheld Combustible Gas Detector
Q1: What environments is this detector suitable for?
A1: It applies to tunnels, industrial workshops and other IIC-class hazardous environments, working stably within -20℃~55℃, ≤98% humidity and ≤8m/s wind speed.
Q2: How to handle inaccurate detection data?
A2: Perform zero calibration in clean air first. If errors persist, conduct standard gas calibration or replace aging sensors, and check for long-term uncalibrated status.
Q3: Can I charge or replace the battery in hazardous areas?
A3: No. Charging and battery replacement are strictly prohibited in dangerous environments to avoid safety accidents, and only designated safe areas are allowed.
Q4: What should I do if the device fails to boot?
A4: Low battery voltage is the main cause. If battery power is sufficient but the device still fails to start, contact the manufacturer for professional maintenance.
Q5: Does it support data recording and export?
A5: Yes. It automatically monitors and stores detection data, and supports infrared export of alarm records with specific time and date for safety inspection and data archiving.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese