Product Description
Introduction of Handheld Gas Leak Detector Industrial
This Pioneer industrial handheld multi-gas detector is an explosion-proof, intrinsically safe device tailored for hazardous IIC explosive gas environments. It simultaneously monitors four core gases: combustible gas (EX), oxygen (O2), carbon monoxide (CO), and hydrogen sulfide (H2S). Featuring sound, light, and vibration triple alarms, it delivers real-time concentration detection and early warnings. Widely applied in petrochemical, fire rescue, shipping, and steel industries, it supports continuous on-site monitoring to secure personnel and property safety with stable and reliable industrial-grade performance.
Feature of Handheld Gas Leak Detector Industrial
1) Multi-gas Precision Detection: Covers full-range detection of 4 common industrial gases with tiny resolution and controlled basic error, ensuring accurate and real-time environmental gas data acquisition.
2) Comprehensive Safety Alarm System: Equipped with two-level adjustable alarm thresholds, triple sound-light-vibration alarms, plus manual emergency, fall and linkage alarm functions for all-round hazard warning.
3) Industrial Durability & Safety: Boasts IP68 protection grade and Ex d ia IIC T4 Gb explosion-proof certification, stably working in -20℃ to 40℃ and high-humidity industrial harsh environments.
4) Long Endurance & Convenient Use: Matches dedicated 2240mAh intrinsic safety battery, supporting over 15 hours of continuous work. It supports one-key zero calibration and regular calibration reminders for easy operation.
5) Powerful Expandable Functions: Supports 100,000 data storage, data export, adjustable screen-off time and password protection. It also connects an external sampling pump for long-distance confined space detection.
Detail photos of Handheld Gas Leak Detector Industrial



Product parameters of Handheld Gas Leak Detector Industrial
| Item | Parameters |
| Detectable Gas Type | Combustible Gas (EX) Oxygen (O₂) Carbon Monoxide (CO) Hydrogen Sulfide (H₂S) |
| Detection Range | EX: (0~100)%LEL O₂: (0.0~30.0)%VOL CO: (0~2000)×10⁻⁶ H₂S: (0~500)×10⁻⁶ |
| Resolution | EX: 1%LEL O₂: 0.1%VOL CO: 1PPM H₂S: 1PPM |
| Basic Error |
EX: 0~100%: ±5%FS O₂: 0.0~5.0%: ±0.5%O₂; 5.0~30.0%: ±3%FS CO: (0~20)×10⁻⁶: ±2×10⁻⁶;(>20~100)×10⁻⁶: ±4×10⁻⁶;(>100~500)×10⁻⁶: ±5% of true value;(>500~1000)×10⁻⁶: ±6% of true value;(>1000~2000)×10⁻⁶: ±10% of true value H₂S: (0~49)×10⁻⁶: ±3×10⁻⁶;(50~500)×10⁻⁶: ±10% of true value |
| Sensor Service Life |
EX: More than 1 year O₂: More than 2 years CO: More than 2 years H₂S: More than 2 years |
| Alarm Performance | Alarm Performance |
| Alarm Signal | Three-dimensional alarm signals: sound, light and vibration |
| Alarm Sound Intensity | >75dB(A) (1 meter away from the buzzer) |
| Alarm Light Visibility | Visible beyond 20m in dark environment |
| Alarm Point Setting Range (Two-stage Alarm) | EX: Full range adjustable; Factory default primary alarm point: 20%LEL, secondary alarm point: 30%LELO₂: Full range adjustable; Factory default primary alarm point: 18.0%O₂, secondary alarm point: 16.0%O₂CO: Full range adjustable; Factory default primary alarm point: 24×10⁻⁶, secondary alarm point: 48×10⁻⁶H₂S: Full range adjustable; Factory default primary alarm point: 10×10⁻⁶, secondary alarm point: 20×10⁻⁶ |
| Alarm Error | EX: ±15%LELO₂: ±0.3%O₂CO: ±1×10⁻⁶H₂S: ±3×10⁻⁶ |
| T90 Response Time (Flow rate: 200mL/min) | EX: ≤30sO₂: ≤35sCO: ≤45sH₂S: ≤45s |
| Basic Functions | Basic Functions |
| Fall Alarm | When the gas concentration is within the standard range, the instrument can detect the fall of the wearer and display the fall mark;When the gas exceeds the limit, the instrument can detect the wearer's fall and display the fall mark. With the linked alarm function enabled, the fall alarm information will be automatically sent to instruments within 100 meters (visible distance). |
| Linked Alarm | When the linked alarm function is enabled, linkage alarm can be realized within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmission power: ≤20dBm. |
| Emergency Alarm | Long press the emergency alarm button to trigger the manual alarm interface and actively send alarm information to surrounding instruments. |
| Calibration Reminder | When enabled, the instrument will trigger a calibration overdue reminder alarm during startup if the calibration expiration date is reached. |
| Temperature and Humidity Detection | The instrument display interface shows real-time ambient temperature and humidity. |
| Password Setting | 4-digit numeric password available for menu access and shutdown permission; factory default: disabled. |
| Factory Reset | Clear stored data and custom settings to restore factory default configuration. |
| Screen Off Time | Adjustable: 0 (always on) or 1~20 minutes standby screen off time. |
| Data Storage | Automatically collect and store detection data, with a maximum storage capacity of 100,000 records. |
| Storage Interval Setting | The time interval for data collection and storage is adjustable. |
| Time Setting | Supports adjustment of year, month, day, hour and minute. |
| Data Export | Alarm data with timestamp can be exported after connecting the instrument to the charging base. |
| Cascade Charging | The charging base supports cascade connection of 20 units, enabling simultaneous charging of 20 devices with a single adapter. |
| External Sampling Pump (Optional) | Compatible with GSP-200 universal gas sampling pump for remote detection in hazardous areas. It features fast detection speed and ensures operator safety. It is applicable to confined space operations and various safety scenarios, widely used in petrochemical, public utilities, fire rescue, shipping, steel and other industries. |
| Power Supply | Power Supply |
| Continuous Working Time | ≥15 hours under normal working conditions*Actual duration depends on operating status, alarm frequency, indicator light activation, calibration overdue warnings and gas over-limit alarms. |
| Battery Specification | Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: 674048-2240mAh; Maximum open-circuit voltage (Uo): 4.2V; Rated operating voltage (Ue): 3.7V. The battery assembly is encapsulated with epoxy resin after being equipped with two-stage series protection circuits, fuses and current-limiting resistors to form an intrinsic safety battery module. |
| Dimension and Weight | Dimension and Weight |
| Overall Dimension | 115.0mm×63.0mm×32.0mm (excluding back clip) |
| Weight | 248g (including back clip) |
| Protection Grade | Protection Grade |
| Ingress Protection Rating | IP68 |
FAQ about Handheld Gas Leak Detector Industrial
Q1: Where can the detector be used?
A1: It applies to 0/1/2 zones of IIC explosive gas environments, suitable for petrochemical, fire rescue, shipping and other industrial scenarios.
Q2: How to handle inaccurate detection data?
A2: Perform zero calibration in clean air first; recalibrate with standard gas if errors persist. Replace aging sensors if problems remain.
Q3: Is charging allowed in hazardous areas?
A3: No. Charging must be done in safe ground areas with the official dedicated charger, and the device must be powered off during charging.
Q4: What is the service life of the sensors?
A4: EX sensor lasts over 1 year; O2, CO and H2S sensors have a service life of more than 2 years under normal use.
Q5: How does the linkage alarm work?
A5: After enabling the function, it realizes 100m visual-distance linkage alarm with other devices, receiving and sending alarm signals in real time.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese