Handheld Natural Gas Leak Detector

Handheld Natural Gas Leak Detector

This Pioneer portable composite gas detector is an explosion-proof, intrinsically safe monitoring device designed for IIC-class explosive gas environments. It precisely detects four common industrial gases: combustible gas (EX), oxygen (O2), carbon monoxide (CO), and hydrogen sulfide (H2S). Adhering to GB3836-2010 and GB12358-2006 standards, it delivers real-time concentration monitoring and triple sound-light-vibration alarms for gas over-limit, oxygen deficiency and safety emergencies. 

Send Inquiry
Product Description

Introduction of Handheld Natural Gas Leak Detector

This Pioneer portable composite gas detector is an explosion-proof, intrinsically safe monitoring device designed for IIC-class explosive gas environments. It precisely detects four common industrial gases: combustible gas (EX), oxygen (O2), carbon monoxide (CO), and hydrogen sulfide (H2S). Adhering to GB3836-2010 and GB12358-2006 standards, it delivers real-time concentration monitoring and triple sound-light-vibration alarms for gas over-limit, oxygen deficiency and safety emergencies. Compact, durable and highly adaptable, it is widely used in petrochemical, fire rescue, shipping and steel industries for on-site safety supervision.

 

Feature of Handheld Natural Gas Leak Detector

1) Multi-Gas High-Precision Detection It supports four-gas simultaneous monitoring with professional sensors. It features accurate resolution and calibrated error control, with customized detection ranges for different gases to meet diverse industrial detection demands.

 

2) Triple Safety Alarm System Equipped with sound, light and vibration dual-stage alarms. The 75dB+ loud alarm and 20-meter visible warning light ensure effective reminders in noisy and dark working environments.

 

3) Intelligent Safety Functions Integrated fall detection, 100m wireless linkage alarm and manual emergency alarm. It also supports calibration reminders and real-time temperature & humidity monitoring for comprehensive site safety protection.

 

4) Industrial-Grade Durability & Safety Boasts IP68 protection grade and Ex d ia IIC T4 Gb explosion-proof certification. It stably works in harsh environments of -20℃ to 40℃, 80–116kPa air pressure and ≤98% humidity.

 

5) Long Endurance & Convenient Charging The customized 2240mAh intrinsic safety battery offers over 15 hours of continuous operation. The cascading charging base supports simultaneous charging of 20 devices, ideal for team batch use.

 

6) Powerful Data Management It stores up to 100,000 monitoring records with adjustable data sampling intervals. Data can be exported via the charging base for safety record filing and analysis.

 

Detail photos of Handheld Natural Gas Leak Detector

Portable Gas Detector with Data Logging

Portable Gas Detector with Data Logging

Portable Gas Detector with Data Logging

 

Product parameters of Handheld Natural Gas Leak Detector

Item Parameters
Detectable Gas Type Combustible Gas (EX) Oxygen (O₂) Carbon Monoxide (CO) Hydrogen Sulfide (H₂S)
Detection Range EX: (0~100)%LEL O₂: (0.0~30.0)%VOL CO: (0~2000)×10⁻⁶ H₂S: (0~500)×10⁻⁶
Resolution EX: 1%LEL O₂: 0.1%VOL CO: 1PPM H₂S: 1PPM
Basic Error

EX: 0~100%: ±5%FS

O₂: 0.0~5.0%: ±0.5%O₂; 5.0~30.0%: ±3%FS

CO: (0~20)×10⁻⁶: ±2×10⁻⁶;(>20~100)×10⁻⁶: ±4×10⁻⁶;(>100~500)×10⁻⁶: ±5% of true value;(>500~1000)×10⁻⁶: ±6% of true value;(>1000~2000)×10⁻⁶: ±10% of true value

H₂S: (0~49)×10⁻⁶: ±3×10⁻⁶;(50~500)×10⁻⁶: ±10% of true value

Sensor Service Life

EX: More than 1 year

O₂: More than 2 years

CO: More than 2 years

H₂S: More than 2 years

Alarm Performance Alarm Performance
Alarm Signal Three-dimensional alarm signals: sound, light and vibration
Alarm Sound Intensity >75dB(A) (1 meter away from the buzzer)
Alarm Light Visibility Visible beyond 20m in dark environment
Alarm Point Setting Range (Two-stage Alarm) EX: Full range adjustable; Factory default primary alarm point: 20%LEL, secondary alarm point: 30%LELO₂: Full range adjustable; Factory default primary alarm point: 18.0%O₂, secondary alarm point: 16.0%O₂CO: Full range adjustable; Factory default primary alarm point: 24×10⁻⁶, secondary alarm point: 48×10⁻⁶H₂S: Full range adjustable; Factory default primary alarm point: 10×10⁻⁶, secondary alarm point: 20×10⁻⁶
Alarm Error EX: ±15%LELO₂: ±0.3%O₂CO: ±1×10⁻⁶H₂S: ±3×10⁻⁶
T90 Response Time (Flow rate: 200mL/min) EX: ≤30sO₂: ≤35sCO: ≤45sH₂S: ≤45s
Basic Functions Basic Functions
Fall Alarm When the gas concentration is within the standard range, the instrument can detect the fall of the wearer and display the fall mark;When the gas exceeds the limit, the instrument can detect the wearer's fall and display the fall mark. With the linked alarm function enabled, the fall alarm information will be automatically sent to instruments within 100 meters (visible distance).
Linked Alarm When the linked alarm function is enabled, linkage alarm can be realized within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmission power: ≤20dBm.
Emergency Alarm Long press the emergency alarm button to trigger the manual alarm interface and actively send alarm information to surrounding instruments.
Calibration Reminder When enabled, the instrument will trigger a calibration overdue reminder alarm during startup if the calibration expiration date is reached.
Temperature and Humidity Detection The instrument display interface shows real-time ambient temperature and humidity.
Password Setting 4-digit numeric password available for menu access and shutdown permission; factory default: disabled.
Factory Reset Clear stored data and custom settings to restore factory default configuration.
Screen Off Time Adjustable: 0 (always on) or 1~20 minutes standby screen off time.
Data Storage Automatically collect and store detection data, with a maximum storage capacity of 100,000 records.
Storage Interval Setting The time interval for data collection and storage is adjustable.
Time Setting Supports adjustment of year, month, day, hour and minute.
Data Export Alarm data with timestamp can be exported after connecting the instrument to the charging base.
Cascade Charging The charging base supports cascade connection of 20 units, enabling simultaneous charging of 20 devices with a single adapter.
External Sampling Pump (Optional) Compatible with GSP-200 universal gas sampling pump for remote detection in hazardous areas. It features fast detection speed and ensures operator safety. It is applicable to confined space operations and various safety scenarios, widely used in petrochemical, public utilities, fire rescue, shipping, steel and other industries.
Power Supply Power Supply
Continuous Working Time ≥15 hours under normal working conditions*Actual duration depends on operating status, alarm frequency, indicator light activation, calibration overdue warnings and gas over-limit alarms.
Battery Specification Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: 674048-2240mAh; Maximum open-circuit voltage (Uo): 4.2V; Rated operating voltage (Ue): 3.7V. The battery assembly is encapsulated with epoxy resin after being equipped with two-stage series protection circuits, fuses and current-limiting resistors to form an intrinsic safety battery module.
Dimension and Weight Dimension and Weight
Overall Dimension 115.0mm×63.0mm×32.0mm (excluding back clip)
Weight 248g (including back clip)
Protection Grade Protection Grade
Ingress Protection Rating IP68

 

FAQ about Handheld Natural Gas Leak Detector

Q1: Where can the detector be used? 

A1: It applies to 0/1/2 zone IIC-class explosive hazardous environments, suitable for petrochemical, fire rescue, shipping and other industrial scenarios for daily gas safety monitoring.

 

Q2: How to calibrate the device correctly? 

A2: Professional staff can perform one-key zero calibration in clean air. Targeted calibration with standard gas is required for regular correction, with stable reading waiting time ranging 1–3 minutes for different gases.

 

Q3: Is on-site charging in hazardous areas allowed? 

A3: No. Charging must be done in safe outdoor areas with the device powered off. Battery replacement and disassembly in hazardous environments are strictly prohibited.

 

Q4: How long is the sensor service life? 

A4: The combustible gas sensor lasts over 1 year, while oxygen, CO and H2S sensors have a service life of more than 2 years under normal use.

 

Q51: What should I do if detection data is inaccurate? 

A5: First perform zero calibration in clean air. If the problem persists, conduct standard gas calibration; long-term inaccuracy indicates sensor aging, requiring professional replacement.

Leave Your Message


Leave a message