Product Description
Introduction of Intrinsically safe Portable Gas Detector
The JD4(A) multi-parameter gas detector is an intrinsically safe and flameproof portable monitoring device certified for coal mine and hazardous industrial environments. Designed for continuous on-site gas detection, it accurately measures four critical gases: methane, oxygen, carbon monoxide, and carbon dioxide. It operates stably under harsh conditions including 0℃–40℃ temperature, ≤98% humidity, and 80–116kPa atmospheric pressure, delivering reliable safety monitoring for underground tunnels and industrial sites.
Compact and lightweight (259.5g with clip), this handheld detector supports both fixed installation and personal portable use. It features real-time temperature and humidity display and long-duration operation, serving as an essential safety tool for mine ventilation staff, field operators and site managers to prevent gas leakage and hypoxia risks.
Feature of Intrinsically safe Portable Gas Detector
1) Four-in-One High-Precision Detection: It covers full-range detection of CH4, O2, CO and CO2 with industry-standard accuracy and fast response. The maximum response time is only 45 seconds, ensuring instant capture of gas concentration changes.
2) Triple Safety Alarm System: Equipped with sound, light and vibration dual-level alarms. The 80dB+ loud alarm and 20-meter visible flash provide clear reminders in noisy and dark working environments, with accurate alarm error control.
3) Rugged IP68 Waterproof & Dustproof Design: It withstands 1.1m deep water immersion for 40 minutes and resists dust intrusion, adapting to humid, dusty and complex underground working conditions for durable long-term use.
4) Smart Customizable Functions: Supports calibration reminder, password protection, adjustable screen-off time and data storage. Optional fall detection and 100m wireless linkage alarm realize team-wide collaborative safety monitoring.
5) Long Endurance & Safe Power Supply: The dedicated intrinsic safety battery ensures over 10 hours of continuous working time. It supports cascaded charging for 20 devices and strictly prohibits underground charging to eliminate explosion risks.
Detail photos of Intrinsically safe Portable Gas Detector



Product parameters of Intrinsically safe Portable Gas Detector
| Item | Parameters |
| Detectable Gas Types | Methane (CH4) Oxygen (O2) Carbon Monoxide (CO) Carbon Dioxide (CO2) |
| Detection Range |
CH4: (0.00~4.00)%CH4 O2: (0.0~30.0)%O2 CO: (0~1000)×10 CO CO2: (0.00~5.00)%CO2 |
| Basic Accuracy Error |
CH4: ±0.10%CH4 (0.00~1.00%)±10% of true value (1.00~3.00%)±0.30%CH4 (3.00~4.00%) O2: ±0.5%O2 (0.0~5.0%)±3%FS (5.0~30.0%) CO: ±2% (0~20×10 CO)±4% (>20~100×10 CO)±5% of true value (>100~500×10 CO)±6% of true value (>500~1000×10 CO) CO2: ±0.10% (0.00~0.50%)±(0.05 + 5% of true value) (0.50~5.00%) |
| Alarm Performance | Alarm Performance |
| Alarm Signal | Three-dimensional alarm: sound, light and vibration |
| Alarm Sound Intensity | ≥80dB(A) (1 meter away from the buzzer) |
| Alarm Visibility (Light) | Visible distance ≥20m in dark environment |
| Two-Stage Alarm Threshold (Full range adjustable) |
CH4: Factory primary alarm point: 1.00%CH4; Secondary alarm point:1.50%CH4 O2: Factory primary alarm point: 18.0%O2; Secondary alarm point: 16.0%O2 CO: Factory primary alarm point: 24×10-6 CO; Secondary alarm point: 48×10-6 CO CO2: Factory primary alarm point: 1.0%CO2; Secondary alarm point: 1.5%CO2 |
| Alarm Error |
CH4: ±0.05%CH4 O2: ±0.3%O2 CO: ±1×10 CO CO2: ±0.04%CO2 |
| Response Time (Flow rate: 250mL/min) |
CH4: ≤20s O2: ≤35s CO: ≤45s CO2: ≤30s |
| Main Functions | Main Functions |
| Fall Alarm (Optional) | The detector can monitor the fall status of the wearer and display the fall icon under normal gas concentration conditions. It can also trigger fall detection when gas concentration exceeds the limit. With linkage alarm enabled, fall alarm signals will be automatically sent to detectors within 100 meters (visible distance). |
| Linkage Alarm (Optional) | When enabled, linkage alarm is available within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmit power: ≤20dBm. |
| Emergency Alarm | Long press the emergency alarm button to activate the manual alarm interface and actively send alarm signals to surrounding detectors. |
| Calibration Reminder | Once enabled, the detector will pop up an over-calibration reminder on startup when the calibration period expires. |
| Temperature & Humidity Detection | Real-time temperature and humidity display on the monitoring interface. |
| Password Setting | 4-digit password available for menu access and shutdown permission; factory default: disabled. |
| Factory Reset | Clear stored data and custom settings to restore factory defaults. |
| Screen-off Time | Adjustable: 0 (always on) or 1~20 minutes. |
| Data Storage Interval | Customizable interval for real-time data collection and storage. |
| Time Setting | Adjustable year, month, day, hour and minute. |
| Data Export | Supports exporting dated alarm data via the dedicated charging base. |
| Cascade Charging (Optional) | The charging base supports cascade connection for up to 20 units, enabling simultaneous charging of 20 detectors with a single adapter. |
| Power Supply | Power Supply |
| Continuous Working Time | ≥10 hours under normal working conditions*Subject to operating status, alarm frequency and activation of indicator lights & reminder functions |
| Battery Specification | Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: QHPW 674048, 1120mAhMaximum open-circuit voltage (Uo): 4.3VMaximum output current (Io): 2.1ARated working voltage (Ue): 3.7VEquipped with two-stage protection circuit and encapsulated with epoxy resin to form an intrinsic safety battery assembly. |
| Dimension & Weight | Dimension & Weight |
| Overall Dimension | Approx. 115.0mm×63.0mm×41.0mm (including back clip) |
| Weight | Approx. 259.50g (including back clip) |
| Protection Grade | Protection Grade |
| IP Rating | IP68 (1.1m water depth, 40 minutes duration) |
FAQ about Intrinsically safe Portable Gas Detector
Q1: What scenarios is this detector suitable for?
A1: It is mainly used for real-time gas monitoring in coal mine roadways and underground working areas, and also applicable to other hazardous environments with explosive gas mixtures.
Q2: Is underground charging or battery replacement allowed?
A2: Absolutely prohibited. All charging and battery replacement operations must be completed in ground safety areas with dedicated X61E power adapter.
Q3: How to handle inaccurate detection data?
A3: Perform zero calibration and standard gas calibration first. If the error persists, the sensor may be aging and needs professional replacement.
Q4: What does the calibration overdue reminder mean?
A4: It indicates the device’s preset calibration period has expired. Calibrate timely to ensure detection accuracy and avoid monitoring errors.
Q5: What causes the device to fail to power on?
A5: The main reason is insufficient battery voltage. Fully charge the device via the dedicated base charger; if the fault remains, contact the manufacturer for maintenance.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese