Portable Ammonia Gas Detector

Portable Ammonia Gas Detector

The Eagle-NH3 portable ammonia gas detector is an intrinsically safe monitoring device developed for hazardous industrial environments. Complying with GB3836-2010 and other authoritative national standards, it features the Ex ia IIC T4 Ga explosion-proof grade, enabling stable operation in flammable and explosive gas scenarios. It is widely applicable for real-time continuous ammonia concentration monitoring in tunnels, chemical workshops and other sites, serving field operators, management and safety inspection personnel.

Send Inquiry
Product Description

Introduction of Portable Ammonia Gas Detector

The Eagle-NH3 portable ammonia gas detector is an intrinsically safe monitoring device developed for hazardous industrial environments. Complying with GB3836-2010 and other authoritative national standards, it features the Ex ia IIC T4 Ga explosion-proof grade, enabling stable operation in flammable and explosive gas scenarios. It is widely applicable for real-time continuous ammonia concentration monitoring in tunnels, chemical workshops and other sites, serving field operators, management and safety inspection personnel.

 

Adopting high-precision electrochemical sensing technology, the detector converts ammonia gas concentration into identifiable electrical signals, which are processed and displayed digitally. Once the gas concentration exceeds the preset threshold, it triggers triple audible, visual and vibration alarms to remind staff of potential risks timely. With a compact and lightweight design, it supports both portable handheld use and fixed on-site monitoring, adapting to diverse working scenarios.

 

Feature of Portable Ammonia Gas Detector

1) High Detection Accuracy & Stability: It delivers precise detection with a ±1%FS indication error and ±1×10⁻⁶NH3 alarm error. The full-range measurable span of 0-100PPM covers conventional ammonia leakage scenarios, with a response time within 45 seconds, ensuring rapid and accurate risk capture.

 

2) Professional Multi-level Alarm System: Equipped with dual high and ultra-high concentration alarms, plus TWA and STEL limit alarms. The factory default alarm thresholds match industrial safety standards, and all alarm points are fully adjustable, meeting customized safety monitoring demands for different working conditions.

 

3) Superior Environmental Adaptability: Boasts an IP68 high-level protection grade, supporting normal work at -20℃ to 55℃, humidity ≤98% and wind speed ≤8m/s. It adapts to harsh industrial environments and outdoor complex working conditions with strong environmental resistance.

 

4) Ultra-long Service Life & Durability: The ammonia sensor has a service life of over 2 years, and the device achieves a continuous working time of up to 2 years with dedicated intrinsic safety lithium batteries. It effectively reduces replacement and maintenance costs for long-term industrial monitoring.

 

5) Humanized & Intelligent Functions: It supports infrared data export, automatic data storage, time and date calibration, and calibration overdue reminder. The optional 4-digit password lock protects parameter settings, avoiding misoperation and ensuring standardized equipment management.

 

Detail photos of Portable Ammonia Gas Detector

Portable Ammonia Gas Detector

Portable Ammonia Gas Detector

Portable Ammonia Gas Detector

Portable Ammonia Gas Detector

 

Product parameters of Portable Ammonia Gas Detector

Item Parameters
Test Gas Ammonia (NH₃)
Test Range NH₃: (0~100)×10⁻⁶
Indicating Error NH₃: ±1%FS
Alarm Point Setting Range High/Ultra-high limit alarm values: Full range adjustable for NH₃; The factory default primary alarm point is set to 10×10⁻⁶ NH₃, and the factory default secondary alarm point is set to 20×10⁻⁶ NH₃.TWA alarm: Full range adjustable; Factory default alarm point: 10PPM.STEL alarm: Full range adjustable; Factory default alarm point: 10PPM.
TWA Time Setting TWA time can be set within 4-16 hours; Factory default setting: 8 hours
Alarm Error NH₃: ±1×10⁻⁶
Alarm Sound Intensity >90dB(A) (at a distance of 1 meter from the buzzer)
Alarm Visibility Distance >20m (in dark environment)
Response Time(Flow rate: 200mL/min) NH₃: ≤45s
Protection Grade IP68
Sensor Service Life NH₃: More than 2 years
Continuous Working Time of Instrument ≥2 years
Overall Dimensions(excluding back clip) 95.0mm(L)×53.0mm(W)×30.0mm(H)
Weight 116g (including back clip)
Battery Specification Intrinsic safety power supply for the instrument: 1 piece of lithium-thionyl chloride battery, Model: ER14335-1.65Ah; Rated operating voltage Ue: 3.6V, maximum open-circuit voltage Uo: 3.7V, maximum output current Io: 0.51A.
Calibration Reminder After activation, the instrument will trigger a calibration overdue reminder alarm during power-on when the calibration expiration time is detected.
Password Setting 4-digit numeric password available for menu access and shutdown operation; disabled by default
Data Storage Automatic collection data storage
Time Setting Year, month, day, hour and minute adjustable
Data Export Infrared export, supporting export of alarm data with specific time and date.

 

 

FAQ about Portable Ammonia Gas Detector

Q1: What environments is this detector suitable for?

A1: It applies to IIC-class explosive gas hazardous environments, tunnels and chemical sites, working stably within -20℃~55℃, 80-116kPa atmospheric pressure and ≤98% humidity.

 

Q2: Can I charge or replace the battery in hazardous areas?

A2: Absolutely not. It is strictly forbidden to charge or replace the battery in dangerous environments to avoid explosion risks, and only the specified ER14335 battery can be used.

 

Q3: How to solve inaccurate detection data?

A3: Inaccurate data is usually caused by zero drift or overdue calibration. Perform zero calibration in clean air first; if invalid, complete standard gas calibration or replace the aging sensor.

 

Q4: What is the alarm intensity of the device?

A4: The alarm sound intensity exceeds 90dB (1 meter away), and the alarm light is visible within 20 meters in dark environments. The triple alarm mode ensures no missed risks in noisy or dim sites.

 