Product Description
Introduction of Portable Combustible Gas Detector Supplier
Our Pioneer portable composite gas detector is a high-precision, explosion-proof detection device tailored for hazardous industrial environments. It simultaneously monitors four core gases: combustible gas (EX), oxygen (O2), carbon monoxide (CO), and hydrogen sulfide (H2S), delivering real-time concentration data to prevent gas leakage and hypoxia risks. With an explosion-proof mark of Ex d ia IIC T4 Gb, it adapts to 0/1/2 zone explosive gas environments, covering petroleum, chemical, fire rescue, shipping and steel industries.
Built for harsh working conditions, the detector features a wide working temperature range of -20℃ to 40℃ and IP68 full protection. It supports continuous 15-hour operation and real-time temperature & humidity display, ensuring stable and reliable all-weather monitoring. Lightweight and compact (248g, 115×63×32mm), it enables easy portable carrying for on-site safety inspection and emergency detection.
Feature of Portable Combustible Gas Detector Supplier
1) Multi-Gas High-Precision Detection: Adopts professional sensors with long service life (over 2 years for most sensors). It provides accurate detection with tiny resolution and segmented error control, meeting strict industrial detection standards.
2) Triple Safety Alarm System: Equipped with sound, light and vibration triple alarms. The 75dB+ loud alarm and 20m visible light ensure effective reminders in noisy and dark environments, with two-level adjustable alarm thresholds.
3) Smart Linked Safety Functions: Supports fall alarm, wireless linkage alarm (100m visible range) and manual emergency alarm. Multiple devices can interactively alert to realize regional safety linkage protection.
4) Durable & Explosion-Proof Design: Adopts flameproof and intrinsically safe structure, strictly compliant with GB3836 and GB12358 standards. IP68 waterproof and dustproof grade resists severe site impacts and corrosion.
5) Rich Practical Functions: Features 100,000-piece data storage, adjustable storage interval and screen-off time, password protection, calibration reminder and one-key zero calibration, supporting data export and batch charging cascade.
Detail photos of Portable Combustible Gas Detector Supplier



Product parameters of Portable Combustible Gas Detector Supplier
| Item | Parameters |
| Detectable Gas Type | Combustible Gas (EX) Oxygen (O₂) Carbon Monoxide (CO) Hydrogen Sulfide (H₂S) |
| Detection Range | EX: (0~100)%LEL O₂: (0.0~30.0)%VOL CO: (0~2000)×10⁻⁶ H₂S: (0~500)×10⁻⁶ |
| Resolution | EX: 1%LEL O₂: 0.1%VOL CO: 1PPM H₂S: 1PPM |
| Basic Error |
EX: 0~100%: ±5%FS O₂: 0.0~5.0%: ±0.5%O₂; 5.0~30.0%: ±3%FS CO: (0~20)×10⁻⁶: ±2×10⁻⁶;(>20~100)×10⁻⁶: ±4×10⁻⁶;(>100~500)×10⁻⁶: ±5% of true value;(>500~1000)×10⁻⁶: ±6% of true value;(>1000~2000)×10⁻⁶: ±10% of true value H₂S: (0~49)×10⁻⁶: ±3×10⁻⁶;(50~500)×10⁻⁶: ±10% of true value |
| Sensor Service Life |
EX: More than 1 year O₂: More than 2 years CO: More than 2 years H₂S: More than 2 years |
| Alarm Performance | Alarm Performance |
| Alarm Signal | Three-dimensional alarm signals: sound, light and vibration |
| Alarm Sound Intensity | >75dB(A) (1 meter away from the buzzer) |
| Alarm Light Visibility | Visible beyond 20m in dark environment |
| Alarm Point Setting Range (Two-stage Alarm) | EX: Full range adjustable; Factory default primary alarm point: 20%LEL, secondary alarm point: 30%LELO₂: Full range adjustable; Factory default primary alarm point: 18.0%O₂, secondary alarm point: 16.0%O₂CO: Full range adjustable; Factory default primary alarm point: 24×10⁻⁶, secondary alarm point: 48×10⁻⁶H₂S: Full range adjustable; Factory default primary alarm point: 10×10⁻⁶, secondary alarm point: 20×10⁻⁶ |
| Alarm Error | EX: ±15%LELO₂: ±0.3%O₂CO: ±1×10⁻⁶H₂S: ±3×10⁻⁶ |
| T90 Response Time (Flow rate: 200mL/min) | EX: ≤30sO₂: ≤35sCO: ≤45sH₂S: ≤45s |
| Basic Functions | Basic Functions |
| Fall Alarm | When the gas concentration is within the standard range, the instrument can detect the fall of the wearer and display the fall mark;When the gas exceeds the limit, the instrument can detect the wearer's fall and display the fall mark. With the linked alarm function enabled, the fall alarm information will be automatically sent to instruments within 100 meters (visible distance). |
| Linked Alarm | When the linked alarm function is enabled, linkage alarm can be realized within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmission power: ≤20dBm. |
| Emergency Alarm | Long press the emergency alarm button to trigger the manual alarm interface and actively send alarm information to surrounding instruments. |
| Calibration Reminder | When enabled, the instrument will trigger a calibration overdue reminder alarm during startup if the calibration expiration date is reached. |
| Temperature and Humidity Detection | The instrument display interface shows real-time ambient temperature and humidity. |
| Password Setting | 4-digit numeric password available for menu access and shutdown permission; factory default: disabled. |
| Factory Reset | Clear stored data and custom settings to restore factory default configuration. |
| Screen Off Time | Adjustable: 0 (always on) or 1~20 minutes standby screen off time. |
| Data Storage | Automatically collect and store detection data, with a maximum storage capacity of 100,000 records. |
| Storage Interval Setting | The time interval for data collection and storage is adjustable. |
| Time Setting | Supports adjustment of year, month, day, hour and minute. |
| Data Export | Alarm data with timestamp can be exported after connecting the instrument to the charging base. |
| Cascade Charging | The charging base supports cascade connection of 20 units, enabling simultaneous charging of 20 devices with a single adapter. |
| External Sampling Pump (Optional) | Compatible with GSP-200 universal gas sampling pump for remote detection in hazardous areas. It features fast detection speed and ensures operator safety. It is applicable to confined space operations and various safety scenarios, widely used in petrochemical, public utilities, fire rescue, shipping, steel and other industries. |
| Power Supply | Power Supply |
| Continuous Working Time | ≥15 hours under normal working conditions*Actual duration depends on operating status, alarm frequency, indicator light activation, calibration overdue warnings and gas over-limit alarms. |
| Battery Specification | Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: 674048-2240mAh; Maximum open-circuit voltage (Uo): 4.2V; Rated operating voltage (Ue): 3.7V. The battery assembly is encapsulated with epoxy resin after being equipped with two-stage series protection circuits, fuses and current-limiting resistors to form an intrinsic safety battery module. |
| Dimension and Weight | Dimension and Weight |
| Overall Dimension | 115.0mm×63.0mm×32.0mm (excluding back clip) |
| Weight | 248g (including back clip) |
| Protection Grade | Protection Grade |
| Ingress Protection Rating | IP68 |
FAQ about Portable Combustible Gas Detector Supplier
Q1: Where can the detector be used?
A1: It applies to IIC class explosive gas environments, suitable for petrochemical, fire rescue, shipping, steel and other industries for personal safety monitoring and confined space detection.
Q2: How long is the working and charging time?
A2: It offers over 15 hours of continuous working time. Full charging takes 4-5 hours with a dedicated base, and charging is only allowed in safe non-hazardous areas.
Q3: How to calibrate the device?
A3: Professional staff can perform one-key zero calibration in clean air. Target gas calibration uses standard gas with fixed flow, and repeated calibration ensures accuracy.
Q4: What is the warranty policy?
A4: The host enjoys a 12-month warranty, and the battery has a 6-month warranty for non-human damage. Unauthorized disassembly and man-made damage are excluded from free warranty.
Q5: Does it support extended detection?
A5: Yes, it can be connected with an optional external sampling pump for long-distance sampling and detection, ensuring safety in dangerous confined spaces.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese