Product Description
Introduction of Portable Gas Detector for Biogas Plant
Biogas plants face constant safety risks from flammable and toxic gases, including combustible gas (EX), oxygen deficiency, carbon monoxide (CO), and hydrogen sulfide (H₂S). This professional portable composite gas detector is specially designed for biogas plant operation, maintenance and confined space operations. Complying with GB3836-2010 and GB12358-2006 standards, it features Ex d ia IIC T4 Gb explosion-proof grade, fully adapting to hazardous explosive environments of biogas production, storage and purification workshops.
Lightweight and durable (248g, IP68 protection), the detector supports 15+ hours of continuous operation. It delivers real-time, accurate gas concentration monitoring with ultra-low error and fast response, effectively eliminating potential hazards in biogas plant daily operations, equipment maintenance and confined space inspections.
Feature of Portable Gas Detector for Biogas Plant
1) Four-in-One Accurate Detection: Simultaneously monitors EX (0-100%LEL), O₂ (0-30.0%VOL), CO (0-2000ppm) and H₂S (0-500ppm), covering all key hazard gases in biogas plants with industry-leading resolution and low detection error.
2) Multi-Dimensional Safety Alarm: Equipped with sound, light and vibration triple alarms and two-level adjustable alarm thresholds. It supports manual emergency alarm, fall alarm and 100m long-distance linkage alarm for team collaborative safety protection.
3) High Adaptability & Explosion-Proof: Certified IIC explosion-proof grade, stable working at -20℃ to 40℃ and ≤98% humidity. IP68 waterproof and dustproof design suits harsh biogas plant working conditions.
4) Smart & User-Friendly Functions: Supports one-key gas zeroing and professional calibration, 100,000 data storage and export, customizable screen off time and password lock, meeting standardized plant safety management.
5) Long Service Life & Low Maintenance: Sensors last over 2 years (EX over 1 year). It adopts dedicated intrinsically safe battery, with safe indoor charging and low failure rate, reducing long-term operation costs.
Detail photos of Portable Gas Detector for Biogas Plant



Product parameters of Portable Gas Detector for Biogas Plant
| Item | Parameters |
| Detectable Gas Type | Combustible Gas (EX) Oxygen (O₂) Carbon Monoxide (CO) Hydrogen Sulfide (H₂S) |
| Detection Range | EX: (0~100)%LEL O₂: (0.0~30.0)%VOL CO: (0~2000)×10⁻⁶ H₂S: (0~500)×10⁻⁶ |
| Resolution | EX: 1%LEL O₂: 0.1%VOL CO: 1PPM H₂S: 1PPM |
| Basic Error |
EX: 0~100%: ±5%FS O₂: 0.0~5.0%: ±0.5%O₂; 5.0~30.0%: ±3%FS CO: (0~20)×10⁻⁶: ±2×10⁻⁶;(>20~100)×10⁻⁶: ±4×10⁻⁶;(>100~500)×10⁻⁶: ±5% of true value;(>500~1000)×10⁻⁶: ±6% of true value;(>1000~2000)×10⁻⁶: ±10% of true value H₂S: (0~49)×10⁻⁶: ±3×10⁻⁶;(50~500)×10⁻⁶: ±10% of true value |
| Sensor Service Life |
EX: More than 1 year O₂: More than 2 years CO: More than 2 years H₂S: More than 2 years |
| Alarm Performance | Alarm Performance |
| Alarm Signal | Three-dimensional alarm signals: sound, light and vibration |
| Alarm Sound Intensity | >75dB(A) (1 meter away from the buzzer) |
| Alarm Light Visibility | Visible beyond 20m in dark environment |
| Alarm Point Setting Range (Two-stage Alarm) | EX: Full range adjustable; Factory default primary alarm point: 20%LEL, secondary alarm point: 30%LELO₂: Full range adjustable; Factory default primary alarm point: 18.0%O₂, secondary alarm point: 16.0%O₂CO: Full range adjustable; Factory default primary alarm point: 24×10⁻⁶, secondary alarm point: 48×10⁻⁶H₂S: Full range adjustable; Factory default primary alarm point: 10×10⁻⁶, secondary alarm point: 20×10⁻⁶ |
| Alarm Error | EX: ±15%LELO₂: ±0.3%O₂CO: ±1×10⁻⁶H₂S: ±3×10⁻⁶ |
| T90 Response Time (Flow rate: 200mL/min) | EX: ≤30sO₂: ≤35sCO: ≤45sH₂S: ≤45s |
| Basic Functions | Basic Functions |
| Fall Alarm | When the gas concentration is within the standard range, the instrument can detect the fall of the wearer and display the fall mark;When the gas exceeds the limit, the instrument can detect the wearer's fall and display the fall mark. With the linked alarm function enabled, the fall alarm information will be automatically sent to instruments within 100 meters (visible distance). |
| Linked Alarm | When the linked alarm function is enabled, linkage alarm can be realized within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmission power: ≤20dBm. |
| Emergency Alarm | Long press the emergency alarm button to trigger the manual alarm interface and actively send alarm information to surrounding instruments. |
| Calibration Reminder | When enabled, the instrument will trigger a calibration overdue reminder alarm during startup if the calibration expiration date is reached. |
| Temperature and Humidity Detection | The instrument display interface shows real-time ambient temperature and humidity. |
| Password Setting | 4-digit numeric password available for menu access and shutdown permission; factory default: disabled. |
| Factory Reset | Clear stored data and custom settings to restore factory default configuration. |
| Screen Off Time | Adjustable: 0 (always on) or 1~20 minutes standby screen off time. |
| Data Storage | Automatically collect and store detection data, with a maximum storage capacity of 100,000 records. |
| Storage Interval Setting | The time interval for data collection and storage is adjustable. |
| Time Setting | Supports adjustment of year, month, day, hour and minute. |
| Data Export | Alarm data with timestamp can be exported after connecting the instrument to the charging base. |
| Cascade Charging | The charging base supports cascade connection of 20 units, enabling simultaneous charging of 20 devices with a single adapter. |
| External Sampling Pump (Optional) | Compatible with GSP-200 universal gas sampling pump for remote detection in hazardous areas. It features fast detection speed and ensures operator safety. It is applicable to confined space operations and various safety scenarios, widely used in petrochemical, public utilities, fire rescue, shipping, steel and other industries. |
| Power Supply | Power Supply |
| Continuous Working Time | ≥15 hours under normal working conditions*Actual duration depends on operating status, alarm frequency, indicator light activation, calibration overdue warnings and gas over-limit alarms. |
| Battery Specification | Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: 674048-2240mAh; Maximum open-circuit voltage (Uo): 4.2V; Rated operating voltage (Ue): 3.7V. The battery assembly is encapsulated with epoxy resin after being equipped with two-stage series protection circuits, fuses and current-limiting resistors to form an intrinsic safety battery module. |
| Dimension and Weight | Dimension and Weight |
| Overall Dimension | 115.0mm×63.0mm×32.0mm (excluding back clip) |
| Weight | 248g (including back clip) |
| Protection Grade | Protection Grade |
| Ingress Protection Rating | IP68 |
FAQ about Portable Gas Detector for Biogas Plant
Q1: Is it suitable for confined space detection in biogas tanks?
A1: Yes. It adapts to 0/1/2 hazardous zones and supports external sampling pump (optional) for long-distance confined space detection, ensuring staff safety.
Q2: How to ensure detection accuracy during long-term use?
A2: It supports regular zero calibration and standard gas calibration, with calibration reminder function to avoid invalid detection caused by overdue calibration.
Q3: Can multiple devices realize collaborative alarm?
A3: Absolutely. Built-in linkage alarm function enables real-time alarm signal transmission within 100m visual distance for overall site risk warning.
Q4: What is the working duration and charging requirement?
A4: It works over 15 hours continuously. Charging must be done in safe non-hazardous areas with original matched charger, taking 4-5 hours for full charge.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese