Product Description
Introduction of Portable Gas Detector with Data Logging
This Pioneer portable multi-gas detector is a rugged, intrinsically safe monitoring device engineered for hazardous industrial environments. It simultaneously detects four critical gases: flammable gas (EX), oxygen (O2), carbon monoxide (CO), and hydrogen sulfide (H2S), delivering real-time concentration data with high precision. Compliant with GB3836-2010 and GB12358-2006 standards, it features an Ex d ia IIC T4 Gb explosion-proof rating, suitable for Zone 0, 1, and 2 explosive gas sites across petrochemical, fire rescue, shipping, and steel industries.
Built with practical industrial usability, the detector supports continuous long-term monitoring and professional data management. It provides triple sound, light, and vibration alarms for gas concentration anomalies, with clear visual reminders of alarm levels. Integrated temperature and humidity monitoring, flexible calibration, and diversified alarm functions make it an all-round safety tool for on-site risk prevention and environmental monitoring.
Feature of Portable Gas Detector with Data Logging
1) High Precision & Long Lifespan Sensors: Equipped with dedicated sensors for four gases, it delivers accurate detection with low resolution errors. Sensors offer over 1-year service life for EX and over 2 years for O2, CO and H2S, reducing frequent replacement costs.
2) Multi-Dimensional Intelligent Alarm System: Supports two-level concentration alarms, manual emergency alarm, fall alarm and calibration expiration reminder. The 100-meter wireless linkage alarm enables synchronous risk alerts among multiple devices for full-site safety protection.
3) Powerful Data Logging & Export Function: Stores up to 100,000 monitoring data entries with adjustable recording intervals. Users can export dated alarm and monitoring data via the charging base for compliance inspection and data analysis.
4) Durable & Portable Industrial Design: Weighs only 248g with compact dimensions, featuring IP68 dust and water resistance. It withstands harsh working conditions of -20℃ to 40℃ and 98% high humidity, ideal for field mobile operations.
5) Flexible Customization & Easy Operation: Allows independent setting of alarm thresholds, screen-off time and operation passwords. It supports one-click gas zeroing and standardized gas calibration, with simple button operation for non-professional daily use.
Detail photos of Portable Gas Detector with Data Logging



Product parameters of Portable Combustible Gas Detector Supplier
| Item | Parameters |
| Detectable Gas Type | Combustible Gas (EX) Oxygen (O₂) Carbon Monoxide (CO) Hydrogen Sulfide (H₂S) |
| Detection Range | EX: (0~100)%LEL O₂: (0.0~30.0)%VOL CO: (0~2000)×10⁻⁶ H₂S: (0~500)×10⁻⁶ |
| Resolution | EX: 1%LEL O₂: 0.1%VOL CO: 1PPM H₂S: 1PPM |
| Basic Error |
EX: 0~100%: ±5%FS O₂: 0.0~5.0%: ±0.5%O₂; 5.0~30.0%: ±3%FS CO: (0~20)×10⁻⁶: ±2×10⁻⁶;(>20~100)×10⁻⁶: ±4×10⁻⁶;(>100~500)×10⁻⁶: ±5% of true value;(>500~1000)×10⁻⁶: ±6% of true value;(>1000~2000)×10⁻⁶: ±10% of true value H₂S: (0~49)×10⁻⁶: ±3×10⁻⁶;(50~500)×10⁻⁶: ±10% of true value |
| Sensor Service Life |
EX: More than 1 year O₂: More than 2 years CO: More than 2 years H₂S: More than 2 years |
| Alarm Performance | Alarm Performance |
| Alarm Signal | Three-dimensional alarm signals: sound, light and vibration |
| Alarm Sound Intensity | >75dB(A) (1 meter away from the buzzer) |
| Alarm Light Visibility | Visible beyond 20m in dark environment |
| Alarm Point Setting Range (Two-stage Alarm) | EX: Full range adjustable; Factory default primary alarm point: 20%LEL, secondary alarm point: 30%LELO₂: Full range adjustable; Factory default primary alarm point: 18.0%O₂, secondary alarm point: 16.0%O₂CO: Full range adjustable; Factory default primary alarm point: 24×10⁻⁶, secondary alarm point: 48×10⁻⁶H₂S: Full range adjustable; Factory default primary alarm point: 10×10⁻⁶, secondary alarm point: 20×10⁻⁶ |
| Alarm Error | EX: ±15%LELO₂: ±0.3%O₂CO: ±1×10⁻⁶H₂S: ±3×10⁻⁶ |
| T90 Response Time (Flow rate: 200mL/min) | EX: ≤30sO₂: ≤35sCO: ≤45sH₂S: ≤45s |
| Basic Functions | Basic Functions |
| Fall Alarm | When the gas concentration is within the standard range, the instrument can detect the fall of the wearer and display the fall mark;When the gas exceeds the limit, the instrument can detect the wearer's fall and display the fall mark. With the linked alarm function enabled, the fall alarm information will be automatically sent to instruments within 100 meters (visible distance). |
| Linked Alarm | When the linked alarm function is enabled, linkage alarm can be realized within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmission power: ≤20dBm. |
| Emergency Alarm | Long press the emergency alarm button to trigger the manual alarm interface and actively send alarm information to surrounding instruments. |
| Calibration Reminder | When enabled, the instrument will trigger a calibration overdue reminder alarm during startup if the calibration expiration date is reached. |
| Temperature and Humidity Detection | The instrument display interface shows real-time ambient temperature and humidity. |
| Password Setting | 4-digit numeric password available for menu access and shutdown permission; factory default: disabled. |
| Factory Reset | Clear stored data and custom settings to restore factory default configuration. |
| Screen Off Time | Adjustable: 0 (always on) or 1~20 minutes standby screen off time. |
| Data Storage | Automatically collect and store detection data, with a maximum storage capacity of 100,000 records. |
| Storage Interval Setting | The time interval for data collection and storage is adjustable. |
| Time Setting | Supports adjustment of year, month, day, hour and minute. |
| Data Export | Alarm data with timestamp can be exported after connecting the instrument to the charging base. |
| Cascade Charging | The charging base supports cascade connection of 20 units, enabling simultaneous charging of 20 devices with a single adapter. |
| External Sampling Pump (Optional) | Compatible with GSP-200 universal gas sampling pump for remote detection in hazardous areas. It features fast detection speed and ensures operator safety. It is applicable to confined space operations and various safety scenarios, widely used in petrochemical, public utilities, fire rescue, shipping, steel and other industries. |
| Power Supply | Power Supply |
| Continuous Working Time | ≥15 hours under normal working conditions*Actual duration depends on operating status, alarm frequency, indicator light activation, calibration overdue warnings and gas over-limit alarms. |
| Battery Specification | Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: 674048-2240mAh; Maximum open-circuit voltage (Uo): 4.2V; Rated operating voltage (Ue): 3.7V. The battery assembly is encapsulated with epoxy resin after being equipped with two-stage series protection circuits, fuses and current-limiting resistors to form an intrinsic safety battery module. |
| Dimension and Weight | Dimension and Weight |
| Overall Dimension | 115.0mm×63.0mm×32.0mm (excluding back clip) |
| Weight | 248g (including back clip) |
| Protection Grade | Protection Grade |
| Ingress Protection Rating | IP68 |
FAQ about Portable Gas Detector with Data Logging
Q1: Where can the detector be charged?
A1: It must be charged in a safe non-hazardous area with the original supporting charger. Charging in explosive dangerous environments is strictly prohibited to avoid safety risks.
Q2: How to solve inaccurate detection data?
A2: Inaccurate data is usually caused by sensor drift or overdue calibration. Perform zero calibration in clean air first; if the problem persists, conduct standard gas calibration or replace aging sensors.
Q3: What is the continuous working time?
A3: The device supports over 15 hours of continuous operation under normal conditions. Runtime may shorten frequently due to frequent alarms and screen lighting.
Q4: How does the linkage alarm work?
A4: After enabling the linkage function, the device receives and sends alarm signals within 100 meters. It synchronously triggers sound-light-vibration alarms on surrounding devices for risk sharing.
Q5: Does it support remote detection?
A5: Yes. It can be connected to an optional external sampling pump to realize long-distance sampling detection of confined and dangerous spaces, ensuring operator safety.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese