Portable Gas Detector with Rechargeable Battery

Portable Gas Detector with Rechargeable Battery

The Pioneer composite portable gas detector is a high-precision, explosion-proof detection device designed for hazardous industrial environments. Compliant with GB3836-2010 and GB12358-2006 national standards, it features Ex d ia IIC T4 Gb explosion-proof grade, enabling safe operation in 0/1/2 zones with IIC-class explosive gas atmospheres. It continuously and accurately monitors four common hazardous gases: combustible gas (EX), oxygen (O2), carbon monoxide (CO) and hydrogen sulfide (H2S), providing reliable safety monitoring for high-risk scenarios.

 

Send Inquiry
Product Description

Introduction of Portable Gas Detector with Rechargeable Battery

The Pioneer composite portable gas detector is a high-precision, explosion-proof detection device designed for hazardous industrial environments. Compliant with GB3836-2010 and GB12358-2006 national standards, it features Ex d ia IIC T4 Gb explosion-proof grade, enabling safe operation in 0/1/2 zones with IIC-class explosive gas atmospheres. It continuously and accurately monitors four common hazardous gases: combustible gas (EX), oxygen (O2), carbon monoxide (CO) and hydrogen sulfide (H2S), providing reliable safety monitoring for high-risk scenarios.

 

Lightweight and compact, this 248g detector with IP68 protection grade adapts to complex working conditions with temperatures from -20℃ to 40℃ and humidity up to 98%. Widely applicable in petrochemical, fire rescue, shipping and steel industries, it delivers real-time gas concentration data and triple sound-light-vibration alarms to prevent personal injury and property loss caused by gas hazards.

 

Feature of Portable Gas Detector with Rechargeable Battery

 

1) Multi-gas High-precision Detection: It supports full-range detection of four gases with distinct professional resolution and minimal basic error. The T90 response time is as fast as 30 seconds, ensuring rapid and accurate capture of gas concentration changes on site.

 

2) Comprehensive Intelligent Alarm System: Equipped with two-level adjustable alarm thresholds, it supports manual emergency alarm, gas over-limit alarm, fall alarm and linkage alarm. Within 100 meters visual range, inter-device linkage warning can be realized to achieve regional safety protection.

 

3) Durable Rechargeable Battery Performance: Adopts dedicated 2240mAh manganese lithium battery with multiple safety protection designs. It offers over 15 hours of continuous working time, and supports 20-unit cascaded charging to improve team equipment management efficiency.

 

4) Powerful Data Management Function: The device stores up to 100,000 sets of detection data with adjustable storage intervals. It supports data export with time and date stamps, facilitating subsequent safety record checking and accident traceability.

 

5) Flexible & Humanized Settings: It integrates zero calibration, gas calibration, timing setting and password protection functions. The auto-screen-off time is adjustable, with calibration reminder and factory reset functions, meeting diverse on-site use and daily maintenance needs.

 

Detail photos of Portable Gas Detector with Rechargeable Battery

Portable Gas Detector with Data Logging

Portable Gas Detector with Data Logging

Portable Gas Detector with Data Logging

 

Product parameters of Portable Gas Detector with Rechargeable Battery

Item Parameters
Detectable Gas Type Combustible Gas (EX) Oxygen (O₂) Carbon Monoxide (CO) Hydrogen Sulfide (H₂S)
Detection Range EX: (0~100)%LEL O₂: (0.0~30.0)%VOL CO: (0~2000)×10⁻⁶ H₂S: (0~500)×10⁻⁶
Resolution EX: 1%LEL O₂: 0.1%VOL CO: 1PPM H₂S: 1PPM
Basic Error

EX: 0~100%: ±5%FS

O₂: 0.0~5.0%: ±0.5%O₂; 5.0~30.0%: ±3%FS

CO: (0~20)×10⁻⁶: ±2×10⁻⁶;(>20~100)×10⁻⁶: ±4×10⁻⁶;(>100~500)×10⁻⁶: ±5% of true value;(>500~1000)×10⁻⁶: ±6% of true value;(>1000~2000)×10⁻⁶: ±10% of true value

H₂S: (0~49)×10⁻⁶: ±3×10⁻⁶;(50~500)×10⁻⁶: ±10% of true value

Sensor Service Life

EX: More than 1 year

O₂: More than 2 years

CO: More than 2 years

H₂S: More than 2 years

Alarm Performance Alarm Performance
Alarm Signal Three-dimensional alarm signals: sound, light and vibration
Alarm Sound Intensity >75dB(A) (1 meter away from the buzzer)
Alarm Light Visibility Visible beyond 20m in dark environment
Alarm Point Setting Range (Two-stage Alarm) EX: Full range adjustable; Factory default primary alarm point: 20%LEL, secondary alarm point: 30%LELO₂: Full range adjustable; Factory default primary alarm point: 18.0%O₂, secondary alarm point: 16.0%O₂CO: Full range adjustable; Factory default primary alarm point: 24×10⁻⁶, secondary alarm point: 48×10⁻⁶H₂S: Full range adjustable; Factory default primary alarm point: 10×10⁻⁶, secondary alarm point: 20×10⁻⁶
Alarm Error EX: ±15%LELO₂: ±0.3%O₂CO: ±1×10⁻⁶H₂S: ±3×10⁻⁶
T90 Response Time (Flow rate: 200mL/min) EX: ≤30sO₂: ≤35sCO: ≤45sH₂S: ≤45s
Basic Functions Basic Functions
Fall Alarm When the gas concentration is within the standard range, the instrument can detect the fall of the wearer and display the fall mark;When the gas exceeds the limit, the instrument can detect the wearer's fall and display the fall mark. With the linked alarm function enabled, the fall alarm information will be automatically sent to instruments within 100 meters (visible distance).
Linked Alarm When the linked alarm function is enabled, linkage alarm can be realized within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmission power: ≤20dBm.
Emergency Alarm Long press the emergency alarm button to trigger the manual alarm interface and actively send alarm information to surrounding instruments.
Calibration Reminder When enabled, the instrument will trigger a calibration overdue reminder alarm during startup if the calibration expiration date is reached.
Temperature and Humidity Detection The instrument display interface shows real-time ambient temperature and humidity.
Password Setting 4-digit numeric password available for menu access and shutdown permission; factory default: disabled.
Factory Reset Clear stored data and custom settings to restore factory default configuration.
Screen Off Time Adjustable: 0 (always on) or 1~20 minutes standby screen off time.
Data Storage Automatically collect and store detection data, with a maximum storage capacity of 100,000 records.
Storage Interval Setting The time interval for data collection and storage is adjustable.
Time Setting Supports adjustment of year, month, day, hour and minute.
Data Export Alarm data with timestamp can be exported after connecting the instrument to the charging base.
Cascade Charging The charging base supports cascade connection of 20 units, enabling simultaneous charging of 20 devices with a single adapter.
External Sampling Pump (Optional) Compatible with GSP-200 universal gas sampling pump for remote detection in hazardous areas. It features fast detection speed and ensures operator safety. It is applicable to confined space operations and various safety scenarios, widely used in petrochemical, public utilities, fire rescue, shipping, steel and other industries.
Power Supply Power Supply
Continuous Working Time ≥15 hours under normal working conditions*Actual duration depends on operating status, alarm frequency, indicator light activation, calibration overdue warnings and gas over-limit alarms.
Battery Specification Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: 674048-2240mAh; Maximum open-circuit voltage (Uo): 4.2V; Rated operating voltage (Ue): 3.7V. The battery assembly is encapsulated with epoxy resin after being equipped with two-stage series protection circuits, fuses and current-limiting resistors to form an intrinsic safety battery module.
Dimension and Weight Dimension and Weight
Overall Dimension 115.0mm×63.0mm×32.0mm (excluding back clip)
Weight 248g (including back clip)
Protection Grade Protection Grade
Ingress Protection Rating IP68

 

FAQ about Portable Gas Detector with Rechargeable Battery

Q1: Where can the device be charged?

A1: All charging operations must be completed in a safe open area with the device powered off. Charging in hazardous explosive environments is strictly prohibited to avoid safety risks.

 

Q2: How to handle inaccurate detection data?

A2: Inaccurate data is usually caused by zero drift or overdue calibration. Place the device in clean air for zero calibration, or perform standard gas calibration; replace aging sensors if the problem persists.

 

Q3: What is the service life of the sensors?

A3: The combustible gas sensor lasts more than 1 year, while oxygen, carbon monoxide and hydrogen sulfide sensors have a service life of over 2 years, ensuring long-term stable detection performance.

 

Q4: Does it support remote detection?

A4: Yes. It can be externally equipped with a GSP-200 universal gas sampling pump (optional) for long-distance sampling and detection, ensuring personnel safety in confined and dangerous spaces.

Leave Your Message


Leave a message