Product Description
Introduction of Portable Methane Gas Detector
The Pioneer Portable Methane Gas Detector is a high-precision, explosion-proof detection device designed for hazardous industrial environments. Certified with Ex d ia IIC T4 Gb explosion-proof grade, it delivers reliable continuous monitoring of methane (combustible gas), oxygen, carbon monoxide and hydrogen sulfide concentrations. Tailored for high-risk scenarios in petrochemical, fire rescue, shipping and steel industries, it adapts to complex working conditions with temperatures from -20℃ to 40℃ and humidity up to 98%, ensuring real-time gas safety monitoring in Zone 0, 1 and 2 explosive gas environments.
Built with professional sensor modules and intelligent micro-control systems, this lightweight detector (only 248g) features an IP68 high protection level for excellent dust and water resistance. It supports long-duration operation and diverse intelligent functions, serving as a portable safety guard for on-site staff. With triple sound, light and vibration alarms, it promptly alerts users to gas concentration abnormalities and potential safety hazards, effectively protecting personnel and property safety.
Feature of Portable Methane Gas Detector
1) Accurate & Stable Detection Performance
Equipped with high-quality dedicated sensors, it supports 0-100%LEL methane detection with 1%LEL resolution and accurate error control. Sensors boast a service life of over 1 year, while other gas sensors last more than 2 years. It achieves fast T90 response within 30 seconds for methane, ensuring timely and reliable data feedback.
2) Multi-dimensional Intelligent Alarm System
It integrates dual-stage gas threshold alarms, manual emergency alarms, fall alarms and linkage alarms. The 75dB+ loud alarm sound and 20-meter visible light alarm ensure effective hazard reminders. The 100-meter wireless linkage function enables synchronous alarm of surrounding devices for group operation safety.
3) Durable & Harsh Environment Adaptability
Featuring IP68 full protection and professional explosion-proof certification, it resists dust, water splash and mechanical impact. It works stably under 80-116kPa air pressure and ≤8m/s wind speed, and supports long-term storage at -40℃ to 60℃, suitable for various harsh industrial sites.
4) Long Battery Life & Convenient Operation
Powered by a dedicated 2240mAh intrinsically safe manganese lithium battery, it provides over 15 hours of continuous working time. It supports safe offline charging via a base, with 20-device cascade charging available. The compact 115×63×32mm body with a back clip is easy to carry and operate with simple one-key calibration and parameter setting.
5) Rich Expandable & Recording Functions
It supports real-time temperature and humidity display, timing calibration reminders and password protection. It can store up to 100,000 detection data with adjustable storage intervals, and data can be exported via the charging base. An optional external sampling pump enables long-distance detection in confined and dangerous spaces.
Detail photos of Portable Methane Gas Detector



Product parameters of Portable Methane Gas Detector
| Item | Parameters |
| Detectable Gas Type | Combustible Gas (EX) Oxygen (O₂) Carbon Monoxide (CO) Hydrogen Sulfide (H₂S) |
| Detection Range | EX: (0~100)%LEL O₂: (0.0~30.0)%VOL CO: (0~2000)×10⁻⁶ H₂S: (0~500)×10⁻⁶ |
| Resolution | EX: 1%LEL O₂: 0.1%VOL CO: 1PPM H₂S: 1PPM |
| Basic Error |
EX: 0~100%: ±5%FS O₂: 0.0~5.0%: ±0.5%O₂; 5.0~30.0%: ±3%FS CO: (0~20)×10⁻⁶: ±2×10⁻⁶;(>20~100)×10⁻⁶: ±4×10⁻⁶;(>100~500)×10⁻⁶: ±5% of true value;(>500~1000)×10⁻⁶: ±6% of true value;(>1000~2000)×10⁻⁶: ±10% of true value H₂S: (0~49)×10⁻⁶: ±3×10⁻⁶;(50~500)×10⁻⁶: ±10% of true value |
| Sensor Service Life |
EX: More than 1 year O₂: More than 2 years CO: More than 2 years H₂S: More than 2 years |
| Alarm Performance | Alarm Performance |
| Alarm Signal | Three-dimensional alarm signals: sound, light and vibration |
| Alarm Sound Intensity | >75dB(A) (1 meter away from the buzzer) |
| Alarm Light Visibility | Visible beyond 20m in dark environment |
| Alarm Point Setting Range (Two-stage Alarm) | EX: Full range adjustable; Factory default primary alarm point: 20%LEL, secondary alarm point: 30%LELO₂: Full range adjustable; Factory default primary alarm point: 18.0%O₂, secondary alarm point: 16.0%O₂CO: Full range adjustable; Factory default primary alarm point: 24×10⁻⁶, secondary alarm point: 48×10⁻⁶H₂S: Full range adjustable; Factory default primary alarm point: 10×10⁻⁶, secondary alarm point: 20×10⁻⁶ |
| Alarm Error | EX: ±15%LELO₂: ±0.3%O₂CO: ±1×10⁻⁶H₂S: ±3×10⁻⁶ |
| T90 Response Time (Flow rate: 200mL/min) | EX: ≤30sO₂: ≤35sCO: ≤45sH₂S: ≤45s |
| Basic Functions | Basic Functions |
| Fall Alarm | When the gas concentration is within the standard range, the instrument can detect the fall of the wearer and display the fall mark;When the gas exceeds the limit, the instrument can detect the wearer's fall and display the fall mark. With the linked alarm function enabled, the fall alarm information will be automatically sent to instruments within 100 meters (visible distance). |
| Linked Alarm | When the linked alarm function is enabled, linkage alarm can be realized within 100 meters (visible distance). Frequency range: 2400~2525MHz; Maximum wireless transmission power: ≤20dBm. |
| Emergency Alarm | Long press the emergency alarm button to trigger the manual alarm interface and actively send alarm information to surrounding instruments. |
| Calibration Reminder | When enabled, the instrument will trigger a calibration overdue reminder alarm during startup if the calibration expiration date is reached. |
| Temperature and Humidity Detection | The instrument display interface shows real-time ambient temperature and humidity. |
| Password Setting | 4-digit numeric password available for menu access and shutdown permission; factory default: disabled. |
| Factory Reset | Clear stored data and custom settings to restore factory default configuration. |
| Screen Off Time | Adjustable: 0 (always on) or 1~20 minutes standby screen off time. |
| Data Storage | Automatically collect and store detection data, with a maximum storage capacity of 100,000 records. |
| Storage Interval Setting | The time interval for data collection and storage is adjustable. |
| Time Setting | Supports adjustment of year, month, day, hour and minute. |
| Data Export | Alarm data with timestamp can be exported after connecting the instrument to the charging base. |
| Cascade Charging | The charging base supports cascade connection of 20 units, enabling simultaneous charging of 20 devices with a single adapter. |
| External Sampling Pump (Optional) | Compatible with GSP-200 universal gas sampling pump for remote detection in hazardous areas. It features fast detection speed and ensures operator safety. It is applicable to confined space operations and various safety scenarios, widely used in petrochemical, public utilities, fire rescue, shipping, steel and other industries. |
| Power Supply | Power Supply |
| Continuous Working Time | ≥15 hours under normal working conditions*Actual duration depends on operating status, alarm frequency, indicator light activation, calibration overdue warnings and gas over-limit alarms. |
| Battery Specification | Intrinsic safety power supply: 2 parallel lithium manganate batteries, Model: 674048-2240mAh; Maximum open-circuit voltage (Uo): 4.2V; Rated operating voltage (Ue): 3.7V. The battery assembly is encapsulated with epoxy resin after being equipped with two-stage series protection circuits, fuses and current-limiting resistors to form an intrinsic safety battery module. |
| Dimension and Weight | Dimension and Weight |
| Overall Dimension | 115.0mm×63.0mm×32.0mm (excluding back clip) |
| Weight | 248g (including back clip) |
| Protection Grade | Protection Grade |
| Ingress Protection Rating | IP68 |
FAQ about Portable Methane Gas Detector
Q1: Where is this detector applicable?
A1: It is widely used in petrochemical, fire rescue, shipping, steel and public utility industries, suitable for Zone 0/1/2 IIC-class explosive gas hazardous environments and confined space operation monitoring.
Q2: How to calibrate the detector correctly?
A2: Only trained professionals can calibrate it. Perform zero calibration in clean air, and conduct standard gas calibration with 20%LEL methane standard gas at a 200mL/min flow rate after stabilizing for 1 minute.
Q3: What are the charging safety requirements?
A3: Charging must be done in a safe area with the device powered off. It is forbidden to charge, disassemble or replace the battery in hazardous environments. Only the original supporting charger and dedicated battery can be used.
Q4: How to handle inaccurate detection data?
A4: First perform zero calibration in clean air. If the problem persists, conduct standard gas calibration regularly. Severe inaccuracy indicates sensor aging, which requires professional sensor replacement and maintenance.
Q5: What is the warranty policy?
A5: The main unit enjoys a 12-month warranty, and the battery has a 6-month warranty for non-human damage. Unauthorized disassembly, man-made damage and over-warranty faults are subject to paid maintenance.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese