Product Description
Introduction of Fixed Gas Detector for Petrochemical Plant
The GTYQ-X01 fixed combustible gas detector is a professional monitoring device tailored for industrial and commercial scenarios, especially suitable for harsh petrochemical plant environments. It consists of a main body and a pluggable gas sensor module, adopting natural diffusion sampling and catalytic combustion sensing technology. Designed for continuous 24-hour monitoring, it displays real-time combustible gas concentration and equipment status via a built-in screen, supporting infrared remote control for zero adjustment, calibration and parameter configuration to meet daily operation and maintenance demands.
Certified with Ex db IIC T6 Gb explosion-proof grade, this detector adapts to Zone 1/2 hazardous areas and IIA, IIB, IIC gas environments with T1-T6 temperature group compatibility. It operates stably in extreme conditions of -40℃ to +70℃ and ≤95% non-condensing humidity. With IP66 protection grade and durable die-cast aluminum alloy housing, it delivers reliable and precise gas leakage detection for petrochemical, chemical and other flammable gas-prone sites.
Feature of Fixed Gas Detector for Petrochemical Plant
1) Premium Explosion-Proof & Industrial Durability: Featuring full Ex db IIC T6 Gb explosion-proof certification and IP66 dustproof waterproof rating, the rugged die-cast aluminum shell resists corrosion and extreme weather, perfectly adapting to petrochemical high-risk hazardous areas.
2) High Detection Accuracy & Stability: Equipped with high-precision catalytic combustion sensors, it provides 0.1%LEL resolution, ±5%LEL full-scale deviation and ≤±3%LEL alarm error. It accurately detects methane, hydrogen, propane and other common petrochemical combustible gases.
3) Fast Response & Timely Alarm: The response time is within 30 seconds, supporting two-stage alarm with factory default 25%LEL low alarm and 50%LEL high alarm. The alarm light is visible beyond 5 meters in darkness, ensuring early risk warning.
4) Convenient Operation & Maintenance: The pluggable sensor module simplifies replacement and maintenance. Infrared remote control enables non-contact zero adjustment, calibration and parameter setting without opening the device shell, improving operational safety and efficiency.
5) Stable Signal & Wide Adaptability: It adopts standard RS485 output with 9600 bps baud rate for stable data transmission. It works normally under 86-106kPa atmospheric pressure and wide temperature/humidity range, fitting diverse complex petrochemical working conditions.
Detail photos of Fixed Gas Detector for Petrochemical Plant




Product parameters of Fixed Gas Detector for Petrochemical Plant
| Product Name | GTYQ-X01 Industrial and Commercial Point-type Combustible Gas Detector |
| Explosion-proof Type | Flameproof |
| Explosion-proof Mark | Mark Ex db IIC T6 Gb |
| Test Gas | Combustible gas (Methane, Hydrogen, Propane) |
| Sensor Type | Catalytic Combustion Type |
| Sampling Method | Natural Diffusion |
| Detection Range | 3%LEL ~ 100%LEL |
| Resolution | 0.1%LEL |
| Operating Voltage | DC24V (±15%) |
| Operating Mode | Continuous Detection |
| Range Indication Deviation | Allowable Error: ±5%LEL |
| Alarm Value Setting Range (Two-stage Alarm) | Factory default low alarm set value: 25%LEL; Factory default high alarm set value: 50%LEL |
| Alarm Error | ≤±3%LEL |
| Alarm Light Visibility | More than 5 meters (in dark environment) |
| Response Time | ≤30s |
| Sensor Service Life | ≤3 years under normal monitoring environment |
| Housing Material | Die-cast Aluminum Alloy |
| Overall Dimension | Approx. 136.8mm×112.5mm×73mm |
| Product Weight | Approx. 612g |
| Output Signal | RS485 |
| Baud Rate | 9600 bps |
| Temperature Range | -40℃ ~ +70℃ |
| Relative Humidity | ≤95% (Non-condensing) |
| Atmospheric Pressure | 86 kPa ~ 106kPa |
| Ingress Protection Rating | IP66 |
| Application Site | Suitable for Zone 1 and Zone 2, IIA, IIB and IIC class gas environments |
FAQ about Fixed Gas Detector for Petrochemical Plant
Q1: What hazardous areas is this detector applicable to?
A1: It is suitable for Zone 1 and Zone 2 explosive hazardous areas, compatible with IIA, IIB, IIC type combustible gas environments and T1-T6 temperature groups, fully meeting petrochemical site safety standards.
Q2: Which gases can the detector monitor?
A2: It is specially designed for common petrochemical combustible gases, including methane, hydrogen and propane, with a detection range of 3%LEL to 100%LEL to cover conventional leakage concentration ranges.
Q3: What is the service life of the sensor?
A3: The catalytic combustion sensor has a service life of up to 3 years under normal monitoring environments, with stable long-term performance and low replacement frequency to reduce operation costs.
Q4: Can it work in extreme temperature and humidity?
A4: Yes. It supports -40℃ to +70℃ wide temperature operation and ≤95% non-condensing relative humidity, adapting to outdoor and high-humidity workshop environments of petrochemical plants.
Q5: How to calibrate and adjust parameters?
A5: The device supports infrared remote control operation. Staff can complete zero adjustment, calibration and parameter setting remotely without disassembling the detector, which is safe and efficient.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese


