Fixed Gas Detector for Petrochemical Plant

Fixed Gas Detector for Petrochemical Plant

The GTYQ-X01 fixed combustible gas detector is a professional monitoring device tailored for industrial and commercial scenarios, especially suitable for harsh petrochemical plant environments. It consists of a main body and a pluggable gas sensor module, adopting natural diffusion sampling and catalytic combustion sensing technology. 

 

Send Inquiry
Product Description

Introduction of Fixed Gas Detector for Petrochemical Plant

The GTYQ-X01 fixed combustible gas detector is a professional monitoring device tailored for industrial and commercial scenarios, especially suitable for harsh petrochemical plant environments. It consists of a main body and a pluggable gas sensor module, adopting natural diffusion sampling and catalytic combustion sensing technology. Designed for continuous 24-hour monitoring, it displays real-time combustible gas concentration and equipment status via a built-in screen, supporting infrared remote control for zero adjustment, calibration and parameter configuration to meet daily operation and maintenance demands.

 

Certified with Ex db IIC T6 Gb explosion-proof grade, this detector adapts to Zone 1/2 hazardous areas and IIA, IIB, IIC gas environments with T1-T6 temperature group compatibility. It operates stably in extreme conditions of -40℃ to +70℃ and ≤95% non-condensing humidity. With IP66 protection grade and durable die-cast aluminum alloy housing, it delivers reliable and precise gas leakage detection for petrochemical, chemical and other flammable gas-prone sites.

 

Feature of Fixed Gas Detector for Petrochemical Plant

1) Premium Explosion-Proof & Industrial Durability: Featuring full Ex db IIC T6 Gb explosion-proof certification and IP66 dustproof waterproof rating, the rugged die-cast aluminum shell resists corrosion and extreme weather, perfectly adapting to petrochemical high-risk hazardous areas.

 

2) High Detection Accuracy & Stability: Equipped with high-precision catalytic combustion sensors, it provides 0.1%LEL resolution, ±5%LEL full-scale deviation and ≤±3%LEL alarm error. It accurately detects methane, hydrogen, propane and other common petrochemical combustible gases.

 

3) Fast Response & Timely Alarm: The response time is within 30 seconds, supporting two-stage alarm with factory default 25%LEL low alarm and 50%LEL high alarm. The alarm light is visible beyond 5 meters in darkness, ensuring early risk warning.

 

4) Convenient Operation & Maintenance: The pluggable sensor module simplifies replacement and maintenance. Infrared remote control enables non-contact zero adjustment, calibration and parameter setting without opening the device shell, improving operational safety and efficiency.

 

5) Stable Signal & Wide Adaptability: It adopts standard RS485 output with 9600 bps baud rate for stable data transmission. It works normally under 86-106kPa atmospheric pressure and wide temperature/humidity range, fitting diverse complex petrochemical working conditions.

 

Detail photos of Fixed Gas Detector for Petrochemical Plant

 

Product parameters of Fixed Gas Detector for Petrochemical Plant

Product Name GTYQ-X01 Industrial and Commercial Point-type Combustible Gas Detector
Explosion-proof Type Flameproof
Explosion-proof Mark Mark Ex db IIC T6 Gb
Test Gas Combustible gas (Methane, Hydrogen, Propane)
Sensor Type Catalytic Combustion Type
Sampling Method Natural Diffusion
Detection Range 3%LEL ~ 100%LEL
Resolution 0.1%LEL
Operating Voltage DC24V (±15%)
Operating Mode Continuous Detection
Range Indication Deviation Allowable Error: ±5%LEL
Alarm Value Setting Range (Two-stage Alarm) Factory default low alarm set value: 25%LEL; Factory default high alarm set value: 50%LEL
Alarm Error ≤±3%LEL
Alarm Light Visibility More than 5 meters (in dark environment)
Response Time ≤30s
Sensor Service Life ≤3 years under normal monitoring environment
Housing Material Die-cast Aluminum Alloy
Overall Dimension Approx. 136.8mm×112.5mm×73mm
Product Weight Approx. 612g
Output Signal RS485
Baud Rate 9600 bps
Temperature Range -40℃ ~ +70℃
Relative Humidity ≤95% (Non-condensing)
Atmospheric Pressure 86 kPa ~ 106kPa
Ingress Protection Rating IP66
Application Site Suitable for Zone 1 and Zone 2, IIA, IIB and IIC class gas environments

 

FAQ about Fixed Gas Detector for Petrochemical Plant

Q1: What hazardous areas is this detector applicable to?

A1: It is suitable for Zone 1 and Zone 2 explosive hazardous areas, compatible with IIA, IIB, IIC type combustible gas environments and T1-T6 temperature groups, fully meeting petrochemical site safety standards.

 

Q2: Which gases can the detector monitor?

A2: It is specially designed for common petrochemical combustible gases, including methane, hydrogen and propane, with a detection range of 3%LEL to 100%LEL to cover conventional leakage concentration ranges.

 

Q3: What is the service life of the sensor?

A3: The catalytic combustion sensor has a service life of up to 3 years under normal monitoring environments, with stable long-term performance and low replacement frequency to reduce operation costs.

 

Q4: Can it work in extreme temperature and humidity?

A4: Yes. It supports -40℃ to +70℃ wide temperature operation and ≤95% non-condensing relative humidity, adapting to outdoor and high-humidity workshop environments of petrochemical plants.

 

Q5: How to calibrate and adjust parameters?

A5: The device supports infrared remote control operation. Staff can complete zero adjustment, calibration and parameter setting remotely without disassembling the detector, which is safe and efficient.

Leave Your Message


Leave a message