Product Description
Introduction of IECEx Flammable Gas Sensor
The CGT-CO2000 gas detector is an IECEx & CE-certified flammable gas sensor engineered for rigorous industrial and energy storage scenarios, perfectly matching the tropical and high-humidity operating conditions of Southeast Asia. Designed for continuous carbon monoxide (CO) monitoring in battery containers, energy storage cabins and industrial hazardous zones, it complies with IIC T6 explosion-proof standards, covering Zone 1/2 explosive gas and dust environments.
With a detection range of 0–2000 ppm, it supports dual-level alarm thresholds (200 ppm low alarm / 500 ppm high alarm) and delivers stable, real-time gas concentration data via standard RS485 communication and dry contact relay output. Built with IP66 full protection grade, it adapts to Southeast Asia’s extreme working environments featuring high temperature, high humidity and frequent weather fluctuations, solving local users’ pain points of unstable detection and short equipment service life caused by harsh climatic conditions.
Feature of IECEx Flammable Gas Sensor
Targeting the core challenges of Southeast Asian industrial users—high operation and maintenance costs, shortage of professional technical personnel, unstable tropical environment operation, and strict regional safety compliance requirements—this sensor integrates multiple industry-leading advantages to reduce long-term operational risks and costs for users.
First, maintenance-free and ultra-long service life cuts operational costs. Local SMEs and industrial factories in Southeast Asia face high recurring expenses from regular equipment calibration and replacement, plus a lack of professional maintenance teams. The CGT-CO2000 sensor features factory pre-calibration, supporting 10-year normal service life without daily calibration and routine maintenance. It eliminates recurring costs of calibration gas and manual debugging, greatly reducing post-installation operational expenditure and solving the regional pain point of high long-term maintenance investment.
Second, tropical environment adaptability ensures stable detection. Southeast Asia’s year-round high temperature (-40℃ to +70℃ working range) and 5%–95% RH high humidity easily cause sensor drift, false alarms and component aging. Adopting high-stability electrochemical sensors and die-cast aluminum alloy waterproof and dustproof housing, the device resists dew condensation, dust blockage and high-temperature aging. It effectively avoids false detection failures caused by tropical climate interference, ensuring accurate monitoring with an error margin within ±10% and zero drift ≤50 ppm.
Third, full certification compliance meets regional safety standards. Strict industrial safety supervision and diverse certification requirements are mandatory in Southeast Asian energy and manufacturing industries. The sensor holds IECEx, ATEx, CE and RoHS full certifications, fully complying with local explosive environment safety specifications. Its standardized explosion-proof structure and reliable grounding design meet IEC60079-1 standards, helping users pass safety inspections smoothly and avoid compliance risks.
Fourth, simple installation and networking lowers technical threshold. Facing the regional shortage of skilled technical workers, the sensor adopts modular design and simple hand-in-hand networking. A single RS485 bus supports up to 32 devices connected in parallel, with optional 120Ω terminal resistance. The plug-and-play wiring mode and intuitive three-color LED status indicators (green normal, yellow fault, red alarm) enable rapid installation and daily judgment without professional training, greatly reducing deployment and labor costs.
Detail photos of IECEx Flammable Gas Sensor



Product parameters of IECEx Flammable Gas Sensor
| Type | Specific parameters |
| Appearance parameter | |
| Pigment | dark grey |
| Shell material | die-casting aluminium |
| Outline dimension | approximately 100 mm × 78 mm × 53 mm |
| Product weight | approximately 415 g |
| Function parameter | |
| Test gas | CO(carbon monoxide) |
| Sensor type | electrochemical sensor |
| Sample mode | natural diffusion |
| Detection range | (0~2000)×10-6 (volume fraction) |
| Operate mode | continuous monitoring |
| Alarm value setting range (Two-level alarm) |
The minimum alarm threshold for production output is set at 200×10-6 (volume fraction). The maximum alarm threshold for the outlet concentration is set at 500×10-6 (volume fraction). |
| Alarm error | ±50×10-6 (volume fraction) |
| Range indication deviation | allowable error: ±80×10-6 (volume fraction) |
| Alarming light visibility | > 5 m (in darkness) |
| Response time | ≤ 30s |
| Call time | ≤ 15s |
| Resolution ratio | 1×10-6 (volume fraction) |
| Zero drift range | ≤50×10-6 (volume fraction) |
| Sensor service life | normal monitoring environment for 15 years |
| Electrical parameters | |
| Working voltage | 18VDC-32VDC |
| Rated voltage | 24VDC |
| Power dissipation | ≤ 1W |
| Working current | ≤ 5 mA |
| Alarm current | ≤ 25mA |
| Maximum current | ≤ 25mA |
| Output signal | RS485 (optional) [The communication address defaults to 1 at factory; a built-in 120Ω matching resistor is not connected by default and can be enabled using a jumper cap] |
| Baud rate | 9600 bps |
| Dry contact 1 – Low alarm relay | Group 1: Contact capacity (resistance load): 1A @30VDC; 300 mA @ 125VAC. Factory default: Open during normal operation, close during alarms, open during power loss. |
| Dry contact 2 – High alarm relay | Group 1: Contact capacity (resistance load): 1A @30VDC; 300 mA @ 125VAC. Factory default: Open during normal operation, close during alarms, open during power loss. |
| Indicate way | |
| Pilot lamp | 3 LED status lights |
| State indication | 1. During normal operation: The green indicator light remains illuminated continuously |
| 2. In case of a malfunction: The yellow indicator light remains constantly illuminated. | |
| 3. Alarm indication: When the lower limit is exceeded, a red light flashes; when the upper limit is exceeded, the red light remains on continuously. | |
| 4. During the upgrade process: Red, yellow, and green lights will flash alternately. | |
| Upgrade and configuration parameters | Can be connected to a computer via the RS485 bus (optional) |
| Certification and protection level | |
| Attestation | ROHS, CE ,ATEx, IECEx |
| Protect grade | IP66 |
| Explosion-proof mark |
II2 G Ex db IIC T6 Gb II2 D Ex tb IIIC T80°C Db |
FAQ about IECEx Flammable Gas Sensor
Q1: Is the sensor suitable for Southeast Asia’s high-temperature and high-humidity tropical environments?
A1: Absolutely. It supports -40℃ to +70℃ wide temperature operation and 5%–95% RH non-condensing humidity adaptation. The IP66 waterproof and dustproof housing and anti-condensation design effectively resist tropical climate interference, preventing sensor drift and failure caused by high humidity and high temperature, ensuring long-term stable operation in Southeast Asian factory and energy storage scenarios.
Q2: Does the device require regular calibration and frequent maintenance?
A2: No regular maintenance is needed. The sensor is factory precisely calibrated with a 10-year ultra-long service life. It requires no daily calibration or routine maintenance, only regular simple dust cleaning of the air inlet. It saves expensive calibration gas costs and manual maintenance fees, perfectly fitting the low-operation-demand needs of Southeast Asian users.
Q3: Can it meet local industrial safety certification requirements?
A3: Fully compliant. It is equipped with IECEx, ATEx, CE, RoHS and other international authoritative certifications, with Ex db IIC T6 Gb explosion-proof grade. It meets safety standards for Zone 1/2 hazardous areas in Southeast Asia, supporting smooth project acceptance and safety inspection.
Q4: Is mass networking deployment difficult for factory batch use?
A4: Very simple. The device supports RS485 bus networking, allowing up to 32 sensors to be connected in parallel in a single system via hand-in-hand wiring. The adjustable terminal resistance and unified 24VDC stable power supply design simplify on-site wiring, reduce engineering costs, and support large-scale batch deployment for energy storage stations and industrial parks.
Q5: How to judge equipment faults and alarm status quickly?
A5: Equipped with intuitive three-color LED indication: green light for normal operation, yellow light for equipment fault, red flashing for low-concentration alarm and steady red light for high-concentration alarm. The status is clear at a glance, enabling on-site staff to quickly identify and handle abnormal situations without professional technical support.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese