Product Description
Introduction of Industrial Natural Gas Leak Detector
The GM-X01 industrial and commercial point-type combustible gas detector is a high-precision monitoring device composed of a main body and a pluggable gas sensor module. It adopts natural diffusion sampling and an electrochemical sensor to continuously monitor carbon monoxide leakage in the environment. Equipped with a real-time display screen, it intuitively shows gas concentration and equipment status, and supports infrared remote control for zero adjustment, calibration and parameter setting, enabling convenient on-site debugging.
Designed for harsh industrial environments, this explosion-proof detector features a robust and compact structure. It is applicable to Zone 1 and Zone 2 hazardous areas, adapting to IIA, IIB, IIC gas environments and T1-T6 temperature groups. With stable continuous detection performance, it provides reliable safety monitoring for industrial and commercial gas leakage prevention.
Feature of Industrial Natural Gas Leak Detector
1) Professional Explosion-proof Performance: It holds Ex db IIC T6 Gb explosion-proof certification, fully compliant with stringent industrial hazardous area standards, ensuring safe operation in flammable and explosive gas environments.
2) Accurate & Fast Detection: It covers a 0-1000×10⁻⁶ detection range with low detection and alarm errors, and a response time of ≤30s, realizing rapid perception of gas leaks.
3) Durable & Reliable: The high-quality electrochemical sensor boasts a 3-year service life in normal monitoring environments. The die-cast aluminum alloy shell ensures solid wear and corrosion resistance.
4) Wide Environmental Adaptability: It works stably at -10℃ to +55℃, 86-106kPa atmospheric pressure and ≤95% non-condensing humidity, suitable for diverse complex working conditions.
5) High-level Protection: IP66 protection grade effectively resists dust and water intrusion, adapting to outdoor and harsh industrial scenarios for long-term stable operation.
6) Easy Operation & Debugging: Pluggable sensor module facilitates replacement and maintenance. Infrared remote control realizes non-contact parameter adjustment, zeroing and calibration efficiently.
Detail photos of Industrial Natural Gas Leak Detector



Product parameters of Industrial Natural Gas Leak Detector
| Parameter Name | Technical Specification |
| Product Name | GM-X01 Industrial and Commercial Point-Type Combustible Gas Detector |
| Explosion-proof Type | Flameproof |
| Explosion-proof Mark | Ex db IIC T6 Gb |
| Test Gas | CO (Carbon Monoxide) |
| Sensor Type | Electrochemical Sensor |
| Sampling Method | Natural Diffusion |
| Detection Range | 0~1000×10-6 (Volume Fraction) |
| Operating Voltage | DC24V(±15%) |
| Operating Mode | Continuous Detection |
| Range Indication Deviation | Allowable Error: ±80×10-6 (Volume Fraction) |
| Alarm Value Setting Range (Two-stage Alarm) | Factory default low-level alarm setting value: 200×10-6 (volume fraction); Factory default high-level alarm setting value: 500×10-6 (volume fraction). |
| Alarm Error | ≤±50×10-6 (Volume Fraction) |
| Alarm Light Visibility | > 5m (In Darkness) |
| Response Time | ≤30s |
| Sensor Service Life | ≤3 years under normal monitoring environment |
| Housing Material | Die-cast Aluminum Alloy |
| Overall Dimension | Approx. 136.8mm×112.5mm×73mm |
| Product Weight | Approx. 616g |
| Maximum Operating Current | 10mA |
| Output Signal | RS485 |
| Baud Rate | 9600 bps |
| Temperature Range | -10℃~+55℃ |
| Relative Humidity | ≤95% (Non-condensing) |
| Atmospheric Pressure | 86 kPa~106kPa |
| Ingress Protection Rating | IP66 |
| Application Site | Suitable for Zone 1 and Zone 2, IIA, IIB and IIC gas environments |
FAQ about Industrial Natural Gas Leak Detector
Q1: What gas does this detector monitor?
A1: It is professionally calibrated for carbon monoxide (CO) detection, dedicated to monitoring CO leakage in industrial and commercial environments.
Q2: What are the default alarm thresholds?
A2: The factory low alarm value is 200×10⁻⁶, and the high alarm value is 500×10⁻⁶, supporting safe threshold warning for gas leakage risks.
Q3: What is the working power requirement?
A3: It operates stably with DC24V (±15%) voltage and a maximum working current of 10mA, featuring low power consumption.
Q4: What output signal does it support?
A4: It adopts standard RS485 signal output with a 9600 bps baud rate, convenient for docking with industrial monitoring systems.
Q5: Where can it be installed?
A5: It is suitable for Zone 1/2 hazardous areas and IIA/IIB/IIC gas environments, widely used in industrial and commercial gas safety monitoring scenarios.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese