Product Description
Introduction of Wall Mounted Combustible Gas Alarm
The GM-X01 wall-mounted combustible gas alarm is a professional fixed detection device tailored for industrial and commercial scenarios. It consists of a main unit and a pluggable sensor module, adopting a natural diffusion sampling method to continuously monitor carbon monoxide leakage in the ambient environment. It supports real-time display of gas concentration and device status, delivering stable and round-the-clock safety monitoring.
Certified with Ex db IIC T6 Gb explosion-proof grade, this alarm adapts to Zone 1 and Zone 2 hazardous environments, covering IIA, IIB, IIC gas types and T1-T6 temperature groups. It features a wide detection range of 0~1000×10-6 volume fraction, meeting the detection demands of most industrial and commercial gas leakage scenarios.
Built with practical industrial-grade design, the device operates steadily under extreme conditions of -10℃ to +55℃ and ≤95% non-condensing humidity. Equipped with standard RS485 output and 9600 bps baud rate, it enables seamless connection with industrial control systems for intelligent safety management.
Feature of Wall Mounted Combustible Gas Alarm
1) High-precision Stable Detection: Adopts high-performance electrochemical sensors with fast response within 30 seconds and controllable detection error. Two-stage alarm thresholds (200/500×10-6) realize hierarchical risk warning for accurate hazard judgment.
2) Premium Explosion-proof & Waterproof Performance: Die-cast aluminum alloy shell features IP66 protection grade and top-tier IIC T6 explosion-proof certification, resisting dust, water and harsh industrial corrosion for long-term stable operation.
3) Flexible & Intelligent Operation: Supports infrared remote control for zero adjustment, calibration and parameter setting, eliminating tedious disassembly operations. The pluggable sensor module greatly simplifies daily maintenance and replacement.
4) Low Power & High Compatibility: Powered by DC24V with a maximum working current of only 10mA, it saves energy efficiently. Standard RS485 signal output ensures excellent compatibility with various industrial monitoring systems.
Detail photos of Wall Mounted Combustible Gas Alarm



Product parameters of Wall Mounted Combustible Gas Alarm
| Parameter Name | Technical Specification |
| Product Name | GM-X01 Industrial and Commercial Point-Type Combustible Gas Detector |
| Explosion-proof Type | Flameproof |
| Explosion-proof Mark | Ex db IIC T6 Gb |
| Test Gas | CO (Carbon Monoxide) |
| Sensor Type | Electrochemical Sensor |
| Sampling Method | Natural Diffusion |
| Detection Range | 0~1000×10-6 (Volume Fraction) |
| Operating Voltage | DC24V(±15%) |
| Operating Mode | Continuous Detection |
| Range Indication Deviation | Allowable Error: ±80×10-6 (Volume Fraction) |
| Alarm Value Setting Range (Two-stage Alarm) | Factory default low-level alarm setting value: 200×10-6 (volume fraction); Factory default high-level alarm setting value: 500×10-6 (volume fraction). |
| Alarm Error | ≤±50×10-6 (Volume Fraction) |
| Alarm Light Visibility | > 5m (In Darkness) |
| Response Time | ≤30s |
| Sensor Service Life | ≤3 years under normal monitoring environment |
| Housing Material | Die-cast Aluminum Alloy |
| Overall Dimension | Approx. 136.8mm×112.5mm×73mm |
| Product Weight | Approx. 616g |
| Maximum Operating Current | 10mA |
| Output Signal | RS485 |
| Baud Rate | 9600 bps |
| Temperature Range | -10℃~+55℃ |
| Relative Humidity | ≤95% (Non-condensing) |
| Atmospheric Pressure | 86 kPa~106kPa |
| Ingress Protection Rating | IP66 |
| Application Site | Suitable for Zone 1 and Zone 2, IIA, IIB and IIC gas environments |
FAQ about Wall Mounted Combustible Gas Alarm
Q1: What gas does this alarm detect?
A1: It is professionally calibrated for carbon monoxide (CO) detection, with a detection range of 0~1000ppm, ideal for CO leakage monitoring in industrial and commercial spaces.
Q2: Where can the detector be installed?
A2: It applies to Zone 1 and Zone 2 hazardous areas, suitable for all IIA, IIB, IIC class gas environments with T1-T6 temperature group requirements.
Q3: How long is the sensor service life?
A3: The electrochemical sensor boasts a service life of up to 3 years under normal monitoring environments, reducing frequent replacement costs.
Q4: Does it support system linkage?
A4: Yes. Equipped with RS485 signal output, it can be connected to industrial control and alarm systems to realize automatic linkage of safety protection devices.
Q5: What is the working environment requirement?
A5: It works stably at -10℃~+55℃, 86-106kPa atmospheric pressure and ≤95% non-condensing humidity, adapting to most harsh indoor industrial environments.
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
Pilipino
Gaeilge
عربى
norsk
اردو
čeština
Ελληνικά
Українська
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
Српски
Afrikaans
Беларус
Монгол хэл
O'zbek
Sundanese
Javanese